Electrode Impedance Measurements on the Cerium(IV) - Cerium(III) Couple in Perchloric Acid Solutions.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HYDROGEN ADSORPTION ON SILVER CATHODES IN PERCHLORIC ACID SOLUTIONS

In this paper studies of overvoltage and capacitance measurements at silver cathodes in aqueous perchloric acid at room temperature are described. Capacitances were deduced from open-circuit potential decay measurements. The increase of overvoltage and the growth of the measured capacitances in the course of electrolysis are attributed to a growing pseudocapacitance component. This is anal...

متن کامل

Considerations on electrical impedance measurements of electrolyte solutions in a four- electrode cell

A tetrapolar probe to measure the electrical properties of electrolyte solutions was implemented with gold electrodes according to the van der Pauw method. Electrical impedance spectroscopy (EIS) measurements of different concentrations of phosphate buffer saline (PBS) solution and an oral mucosal tissue sample dispersed in PBS were performed in the galvanostatic mode using a four-electrode cel...

متن کامل

Utilization of impedance measurements in pallidotomy using a monopolar electrode.

OBJECT This study was performed to evaluate the reliability and utility of using monopolar impedance monitoring for estimation of the location of the thermocouple electrode during a pallidotomy procedure. METHODS In 26 patients, impedance profiles were measured at 2-mm intervals and anatomical boundaries were marked on postoperative MRI studies in 19 patients. The pattern of change in impedan...

متن کامل

Planar electrode array systems for neural recording and impedance measurements

Systems designed to significantly reduce equipment cost and size for neurophysiological studies and hybrid biosensor applications were developed. Custom integrated circuits, each providing eighteen channels of amplification and filtering were designed, fabricated and tested. Planar arrays of iridium microelectrodes were fabricated and packaged in a standard 40 pin dual-in-line package for cultu...

متن کامل

Electrode-Skin contact impedance: In vivo measurements on an ovine model

The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Acta Chemica Scandinavica

سال: 1956

ISSN: 0904-213X

DOI: 10.3891/acta.chem.scand.10-1345