Electrochemical Study of Anodized Titanium in Phosphoric Acid
نویسندگان
چکیده
منابع مشابه
Controlling Electrochemical Chaos in the Copper-Phosphoric Acid System
Model calculations indicate that chaotic current oscillations during anodic electrodissolution of copper into phosphoric acid may be controlled by applying a simple map-based algorithm. In the experiments, the unstable period-one and period-two orbits embedded in the chaotic attractor have been stabilized by small perturbations of the anodic potential. We present the results of an experimental ...
متن کاملInvestigation of resistive switching in anodized titanium dioxide thin films
In this work, TiO2 nanostructures were grown on titanium thin films by electrochemical anodizing method. The bipolar resistive switching effect has been observed in Pt/TiO2/Ti device. Resistive switching characteristics indicated the TiO2 nanotubes are one of the potential materials for nonvolatile memory applications. Increasing anodizing duration will increase nanotube lengths which itself c...
متن کاملBacterial adherence to anodized titanium alloy
The aim of this study was to evaluate Staphylococcus sp adhesion to modified surfaces of anodized titanium alloy (Ti-6Al-4V). Surface modification involved generation of fluoride-containing titanium oxide nanotube films. Specimens of Ti-6Al-4V alloy 6-4 ELIgrade 23meets the requirements of ASTM F136 2002A (AMS 2631B class A1) were anodized in a mixture of sulphuric/hydrofluoric acid at 20 V for...
متن کاملImproved in vitro angiogenic behavior on anodized titanium dioxide nanotubes
BACKGROUND Neovascularization over dental implants is an imperative requisite to achieve successful osseointegration onto implanted materials. The aim of this study was to investigate the effects on in vitro angiogenesis of anodized 70 nm diameter TiO2 nanotubes (NTs) on Ti6Al4V alloy synthesized and disinfected by means of a novel, facile, antibacterial and cost-effective method using super ox...
متن کاملBiological responses of anodized titanium implants under different current voltages.
The oxide layer of a titanium surface is very stable, and seems to result in excellent biocompatibility and successful osseointegration. The purpose of this study was to investigate the effects of high anodic oxidation voltages on the surface characteristics of titanium implants and the biologic response of rabbit tibiae. Bone tissue responses were evaluated by removal torque tests and histomor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Materials Science and Engineering
سال: 2020
ISSN: 1687-8434,1687-8442
DOI: 10.1155/2020/5769071