Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reducing Impedance Fluctuation by Electrode Structure for Electrochemical Impedance Spectroscopy

In this paper, we investigated the electrode structure of the electrical bio-sensor to reduce impedance measurement fluctuation. Five pairs of the same electrodes were formed on the PCB substrate, and a fluidic channel was constructed with a double-sided tape and polycarbonate cover so that all the electrodes had the same reagent distribution. In order to find an electrode structure with little...

متن کامل

DNA Hybridization Sensors Based on Electrochemical Impedance Spectroscopy as a Detection Tool

Recent advances in label free DNA hybridization sensors employing electrochemical impedance spectroscopy (EIS) as a detection tool are reviewed. These sensors are based on the modulation of the blocking ability of an electrode modified with a probe DNA by an analyte, i.e., target DNA. The probe DNA is immobilized on a self-assembled monolayer, a conducting polymer film, or a layer of nanostruct...

متن کامل

An integrated approach to electrochemical impedance spectroscopy

A philosophy for electrochemical impedance spectroscopy is presented which integrates experimental observation, model development, and error analysis. This approach is differentiated from the usual sequential model development for given impedance spectra by its emphasis on obtaining supporting observations to guide model selection, use of error analysis to guide regression strategies and experi...

متن کامل

Sensing Estrogen with Electrochemical Impedance Spectroscopy

This study demonstrates the application feasibility of electrochemical impedance spectroscopy (EIS) in measuring estrogen (17β-estradiol) in gas phase. The present biosensor gives a linear response (R2 = 0.999) for 17β-estradiol vapor concentration from 3.7 ng/L to 3.7 × 10-4 ng/L with a limit of detection (3.7 × 10-4 ng/L). The results show that the fabricated biosensor demonstrates better det...

متن کامل

Using electrochemical impedance spectroscopy of salicylate anion selective electrode: simulation for behavior of electrode

In this paper, the behavior of the salicylate anion-selective electrode was studied using the electrochemical impedance spectroscopy technique. Considering the diagram of the charge transfer resistance and -logarithm of the double layer capacitance versus -logarithm of the concentration, linear range concentration increased to 1.0×10^{-8}-1.0×10^{-1} M and 1.0×10^{-9}-1.0×10^{-1} M, respectivel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Visualized Experiments

سال: 2018

ISSN: 1940-087X

DOI: 10.3791/56611