Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization

AIM The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. STUDY DESIGN A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted hum...

متن کامل

HyFlex nickel-titanium rotary instruments after clinical use: metallurgical properties.

AIM To analyse the type and location of defects in HyFlex CM instruments after clinical use in a graduate endodontic programme and to examine the impact of clinical use on their metallurgical properties. METHODOLOGY A total of 468 HyFlex CM instruments discarded from a graduate endodontic programme were collected after use in three teeth. The incidence and type of instrument defects were anal...

متن کامل

Cyclic fatigue of Profile rotary instruments after simulated clinical use.

AIM The purpose of this study was to evaluate cyclic fatigue of Profile Ni-Ti rotary instruments (PRIs) after dry heat sterilization and up to 10 times simulated clinical use. METHODOLOGY Instruments of size 40-15 were used in a crown-down technique. Three groups were included in this study. In groups 1 and 2, each set of instruments was used in five and 10 canals, respectively. Group 3 was t...

متن کامل

SEM evaluation of canal wall dentine following use of Mtwo and ProTaper NiTi rotary instruments.

AIM To compare using scanning electron microscopy (SEM) root canal walls following instrumentation in vitro with two different rotary NiTi instruments. The hypothesis was that no difference should be observable between the experimental groups in terms of debris on canal walls and surface morphology. METHODOLOGY Twenty-four single-rooted human teeth were selected. Two types of NiTi instruments...

متن کامل

Comparison of Two Canal Preparation Techniques Using Mtwo Rotary Instruments

INTRODUCTION Root canal preparation is an important process in endodontic therapy. Nickel-titanium (NiTi) rotary file system can be used in single length technique (simultaneous technique) without early coronal enlargement, as well as in crown-down method. The purpose of this in vitro study was to compare single length with crown-down methods' shaping ability using Mtwo NiTi files. MATERIALS ...

متن کامل