Electrochemical behavior and voltammetric determination of pyrazinamide using a poly-histidine modified electrode
نویسندگان
چکیده
منابع مشابه
Electrochemical behavior and voltammetric determination of theophylline at a glassy carbon electrode modified with graphene/nafion.
An ultrasensitive voltammetric sensor, a simply coated graphene-Na?on suspension on a glass carbon electrode surface, was fabricated and used to investigate the electrochemical behavior of theophylline as described in the present paper. The results indicated that this voltammetric sensor exhibited a special recognition capacity to determine theophylline as well as having high sensitivity due to...
متن کاملVoltammetric Determination of α-Lipoic Acid using Poly(Vanillin) Modified Platinum Electrode
In the present study electrochemical detection of α-lipoic acid (α-LA) was carried out with a poly(Vanillin) modified platinum electrode p(VA)/PtE in Brinton Robinson buffer (BR) solution. The platinum electrode surface’s was modified with cyclic voltammetry method. The prepared Pt electrode was characterized by cyclic voltammetry in ferrocyanide and scanning electron microscopy (SEM) images. T...
متن کاملElectrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode
In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...
متن کاملElectrochemical Behavior and Highly Sensitive Voltammetric Determination of Doxepin in Pharmaceutical Preparations and Blood Serum Using Carbon Ionic Liquid Electrode
In this manuscript, the electrocatalytic oxidation of doxepin (DOX) was studied at a carbon ionic liquid electrode, fabricated using graphite, and the ionic liquid 1-octylpyridinium hexaflourophosphate (OPFP). The surface of the proposed electrode was characterized by scanning electron microscopy. Differential pulse voltammetry was applied as an analytical technique for quantification of sub-mi...
متن کاملSensitive Voltammetric Determination of Acetaminophen at Poly(4-vinyl pyridine)/Graphene Composite Modified Electrode
This study demonstrates the use of a selective and sensitive voltammetric sensor for determination of acetaminophen (AC). This was performed by modifying a glassy carbon electrode with composite film of poly(4-vinylpyridine) and graphene sheet (P4VP/GR-GCE). The redox peak currents of AC increased significantly at P4VP/GR-GCE. The result was achieved by the synergistic effect of combined elect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electroanalytical Chemistry
سال: 2013
ISSN: 1572-6657
DOI: 10.1016/j.jelechem.2012.11.032