Electro-welded lattice reinforcement in reinforced concrete ribbed slabs
نویسندگان
چکیده
Shear strength of precast concrete ribbed slabs reinforced with electro-welded lattice girders variable height is experimentally verified. Technical justification given for the use high latticework in reinforcement lightweight double-tee and 30 cm thickness. It was established that contribution to shear always higher than expected values according Spanish standards. Furthermore, as low exhibited lower ultimate ones based on standards, need arose provide an adequate lattices ensure anchorage compressed area order develop strut-and-tie mechanisms. Consequently, approximately 80% specimen are highly recommended slabs, when length chords 20 cm.
منابع مشابه
OPTIMAL DESIGN OF REINFORCED CONCRETE ONE-WAY RIBBED SLABS USING IMPROVED TIME EVOLUTIONARY OPTIMIZATION
In this paper, a new robust metaheuristic optimization algorithm called improved time evolutionary optimization (ITEO) is applied to design reinforced concrete one-way ribbed slabs. Geometric and strength characteristics of concrete slabs are considered as design variables. The optimal design is such that in addition to achieving the minimum cost, all design constraints are satisfied under Amer...
متن کاملMOUTH BROODING FISH ALGORITHM FOR COST OPTIMIZATION OF REINFORCED CONCRETE ONE-WAY RIBBED SLABS
In this paper, the optimum design of a reinforced concrete one-way ribbed slab, is presented via recently developed metaheuristic algorithm, namely, the Mouth Brooding Fish (MBF). Meta-heuristics based on evolutionary computation and swarm intelligence are outstanding examples of nature-inspired solution techniques. The MBF algorithm simulates the symbiotic interaction strategies adopted by org...
متن کاملBehaviour of fibre reinforced concrete slabs
This paper presents a comparison of the properties of concrete slabs when two types of fibres are added. One specimen had no fibres and acted as a control specimen. The remaining four specimens had steel and polypropylene fibres added in the volumetric ratio of 0.5% and 1.0%. The dimensions of the slab specimens were 820×820×80 mm and were supported by four rollers at their edges. A displacemen...
متن کاملStructural Consideration in Design of Reinforced Concrete Slabs with Openings
Over 90% of framed structures in Uganda are built from reinforced concrete. Prior to the 1990’s, most buildings had no openings in slabs, yet in city centers buildings butt against each other with widows at front and back only. This limited retail activities to front rooms of the ground floor and the buildings had to be narrow. A baseline survey of 50 shopping malls in Kampala Central Business ...
متن کاملPunching shear strength of steel fibre reinforced concrete slabs
The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional methods of strengthening against punching, steel fibre reinforcement has proved to be an effective and viable alternative. The addition of fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Gra?evinar
سال: 2021
ISSN: ['1849-1898', '1333-9095', '0350-2465']
DOI: https://doi.org/10.14256/jce.3038.2020