Electrical impedance tomography using induced and injected currents
نویسندگان
چکیده
منابع مشابه
An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography 613 An Algorithm for Applying Multiple Currents Using Voltage Sources in Electrical Impedance Tomography
A method to produce a desired current pattern in a multiple-source EIT system using voltage sources is presented. Application of current patterns to a body is known to be superior to the application of voltage patterns in terms of high spatial frequency noise suppression, resulting in high accuracy in conductivity and permittivity images. Since current sources are difficult and expensive to bui...
متن کاملApplications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملImproved methods to determine optimal currents in electrical impedance tomography
An electrical impedance tomography (EIT) system that uses the optimal current method to inject currents and the regularized Newton-Raphson algorithm to reconstruct an image of resistivity distribution is discussed. Iterative methods to derive the optimal current patterns through iterative physical measurements are developed. Direct methods to first determine the resistance matrix of a resistivi...
متن کاملInduced current magnetic resonance-electrical impedance tomography.
Magnetic resonance-electrical impedance tomography (MR-EIT) is a conductivity imaging method based on injecting currents into the object. In this study, a new MR-EIT method, whereby currents are induced inside the object by using external coils, is proposed. This new method is called induced current magnetic resonance-electrical impedance tomography. In induced current MR-EIT surface electrodes...
متن کاملImaging UXO Using Electrical Impedance Tomography
This paper reports the results of tests where electrical impedance tomography (EIT) was evaluated as a tool for detecting and locating buried unexploded ordnance (UXO). The method relies on the electrolytic polarization induced at the boundary between soil and buried metal. This induced polarization (IP) produces a measurable phase delay between the electric current imposed on the subsurface an...