Electrical impedance tomography system based on active electrodes

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical impedance tomography system based on active electrodes.

Electrical impedance tomography (EIT) can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key difficulties in EIT instrumentation make such monitoring difficult: (1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, a...

متن کامل

Active Electrode Based Electrical Impedance Tomography System

Abstract: EIT can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key di culties in EIT instrumentation make such monitoring di cult: 1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, and 2) EIT electrodes are di c...

متن کامل

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Design and development of Electrical Impedance Tomography (EIT) based System

Electrical Impedance Tomography (EIT) is relatively a new imaging technique with which the images of the internal impedance of the region of interest in human body can be constructed effectively without prolonged exposure to radiations. EIT is fast, inexpensive and portable as compared to other imaging techniques. The presented work focuses on construction of human organ images acquired from im...

متن کامل

Monotonicity-based Electrical Impedance Tomography Lung Imaging

This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography(EIT). The EIT data (i.e., the boundary current-voltage data) can be decomposed into pulmonary, cardiac and other parts using their different periodic natures. The time-differential current-voltage operator corresponding to lung ventila...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physiological Measurement

سال: 2012

ISSN: 0967-3334,1361-6579

DOI: 10.1088/0967-3334/33/5/831