Electrical Discharge Induced by Ultra-Short High-Power Laser<br>-Triggering and Guiding Effect-
نویسندگان
چکیده
منابع مشابه
Triggering and guiding HV discharge in air by filamentation of single and dual fs pulses.
The triggering and guiding of the stationary high voltage (HV) discharges at 5-40 kV are demonstrated by using plasma filaments generated by single and dual femtosecond(fs) laser pulses in air. A significant reduction of the breakdown voltage threshold due to the pre-ionization of the air gap by laser pulse filamentaion was observed. The amount of free electrons of filaments generated by differ...
متن کاملTriggering and Guiding of High-voltage Tesla Coil Discharges by Femtosecond Laser-induced Plasma Filaments in Air
We report experimental guiding of high-voltage (HV) sparks discharges in air with plasma filaments generated by a terawatt femtosecond laser. Large sparks discharges are shoot up from a HV electrode fixed at the top of a Tesla coil voltage elevator to a farther grounded one. Ultrashort laser pulsed beams of energy on the order of the mJ through open air exhibit non-linear propagation effects. I...
متن کاملPartial discharge signal detection using ultra high frequency method in high voltage power equipments: a review
Partial discharge (PD) can be detected using ultra high frequency (UHF) method to increase the detection threshold and to improve the performance of on-line measurement of PD in noise environment. The PD emitted energy as electromagnetic emission, acoustic emission and ozone and nitrous oxide gases. We can use this emitted energy to detected PD signal. The best method to detect PD in gas insula...
متن کاملTriggering and guiding megavolt discharges by use of laser-induced ionized filaments.
We have demonstrated the ability to trigger and guide high-voltage discharges with ionized filaments generated by femtosecond terawatt laser pulses. The plasma filaments extended over the whole gap, providing a direct ohmic connection between the electrodes. Laser-guided straight discharges have been observed for gaps of as much as 3.8 m at a high voltage reduced to 68% of the natural breakdown...
متن کاملSuitability of Ultra High Frequency Partial Discharge Measurement for Quality Assurance and Testing of Power Transformers
Well known reasons for local failures in power transformers are caused by partial discharges (PD) in the electric insulation. Continuous deterioration over time increases the defect which finally can lead to a breakdown of the entire insulation. The importance of PD measurement is accommodated by standardized electrical measurement according to IEC 60270 [1] which is required for acceptance cer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Fundamentals and Materials
سال: 2005
ISSN: 0385-4205,1347-5533
DOI: 10.1541/ieejfms.125.1059