Electric Filed Intensity of the Lightning Strikes on Lightning Air Terminals Installed on Building Structures
نویسندگان
چکیده
منابع مشابه
Impact of lightning strikes on hospital functions.
Two regional hospitals were struck by lightning during a one-month period. The first hospital, which had 236 beds, suffered a direct strike to the building. This resulted in a direct spread of the power peak and temporary failure of the standard power supply. The principle problems, after restoring standard power supply, were with the fire alarm system and peripheral network connections in the ...
متن کاملWhen lightning strikes twice.
The educational, occupational, and creative accomplishments of the profoundly gifted participants (IQs > 160) in the Study of Mathematically Precocious Youth (SMPY) are astounding, but are they representative of equally able 12-year-olds? Duke University’s Talent Identification Program (TIP) identified 259 young adolescents who were equally gifted. By age 40, their life accomplishments also wer...
متن کاملLightning Interception on Elevated Building
-Lightning protection air terminals are placed on structures and other grounded objects with the purpose of capturing the lightning stroke. A well estimation of the lateral protection distance is crucial in predicting the protection area of the lightning rod. This paper focus on a 3-D numerical modelling of lightning attachment based on physical phenomena leading to the formation and the develo...
متن کاملElectrical Injuries and Lightning Strikes
Electrical burn injuries account for about 5% of burns unit admissions. Electricians and linesmen are at highest risk but those working with electrical tools also form a significant proportion of this patient group. [2] Electrical injuries in children are unusual and are mainly due to misguided exploration outside the home. [3] For every death, there are two serious injuries and 36 reported ele...
متن کاملElectromagnetic Field Due to Lightning Strikes to Mountainous Ground
The produced electric and magnetic fields due to lightning strikes to mountainous ground are determined in this paper. For the sake of simplicity a cone-shaped ground with finite conductivity is assumed to represent a natural nonflat ground. By this assumption, we deal with an axillary symmetrical structure so we use the cylindrical 2D-FDTD to save the simulation memory and time, dramatically. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Electrical and Computer Engineering (IJECE)
سال: 2017
ISSN: 2088-8708,2088-8708
DOI: 10.11591/ijece.v7i6.pp3105-3113