منابع مشابه
An automatic interference refractometer.
Interference refractometry is a well-established method of determining the concentration of anaesthetic agents in gas mixtures. A photo-electric detector system has been fitted to a small portable, direct-reading interference refractometer to display automatically the concentration of the agent being measured. The design of the instrument is described and two possible methods of information dis...
متن کاملThe spatially resolved refractometer.
PURPOSE To investigate factors controlling the aberrations of the eye, including accommodation, wavelength, and the apodization of the optics of the eye by cone directional selectivity. METHODS We constructed a new implementation of the Spatially Resolved Refractometer (SRR). This is an instrument, based on the Scheiner principle, that allows the rapid psychophysical measurement of the comple...
متن کاملOptofluidic refractometer using resonant optical tunneling effect.
This paper presents the design and analysis of a liquid refractive index sensor that utilizes a unique physical mechanism of resonant optical tunneling effect (ROTE). The sensor consists of two hemicylindrical prisms, two air gaps, and a microfluidic channel. All parts can be microfabricated using an optical resin NOA81. Theoretical study shows that this ROTE sensor has extremely sharp transmis...
متن کاملA spectroscopic refractometer based on plasmonic interferometry
We describe the design, fabrication, and testing of a spectroscopic refractometer that employs plasmonic interferometry to measure the optical dielectric functions of materials in the visible range. The proposed device, dubbed a plasmonic refractometer, consists of an array of slit-groove plasmonic interferometers etched in a 300 nm-thick metal film (silver or gold) with arm lengths varying in ...
متن کاملLiquid refractometer based on immersion diffractometry.
This study presents a laser diffractometric refractometer for measuring the refractive index of liquids. The refractive index is determined by rotating a reflection grating that is immersed in the fluid under test, and measuring the first-order Littrow diffraction angle. The Littrow angle is easily detected form the interferogram formed by the diffracted beam from the grating and the reflected ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Zeitschrift für analytische Chemie
سال: 1893
ISSN: 0016-1152
DOI: 10.1007/bf01368804