Efficient nonlinear algorithm for envelope detection in white light interferometry

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficient nonlinear algorithm for envelope detection in white light interferometry

A compact and efficient algorithm for digital envelope detection in white light interferograms is derived from a well-known phase-shifting algorithm. The performance of the new algorithm is compared with that of other schemes currently used. Principal criteria considered are computational efficiency and accuracy in the presence of miscalibration. The new algorithm is shown to be near optimal in...

متن کامل

High Precision Signal Processing Algorithm for White Light Interferometry

A new signal processing algorithm for absolute temperature measurement using white light interferometry has been proposed and investigated theoretically. The proposed algorithm determines the phase delay of an interferometer with very high precision (.

متن کامل

Bayesian Estimation for White Light Interferometry

In this thesis, a new approach for the reconstruction of height maps from scanning white light interferometry is presented. This method unifies the conventional steps of preand postprocessing within Bayesian inference. An adept formulation of the prior allows for the exact computation of the height estimate, obviating the need for stochastic sampling or simulation methods. In conventional surfa...

متن کامل

Basics of White-Light Interferometry

Interferometer Setup The Twyman–Green interferometer (Figure 1) is a special configuration of the well-known Michelson interferometer with optics that superimpose the images of the object and the reference planes. Polytec engineers use this interferometer and place a CCD image sensor like those used for digital photography at the point where the two images are superimposed. A broadband “white-l...

متن کامل

Moiré interferometry with white light.

While high-sensitivity moiré interferometry requires monochromatic light, an auxiliary compensator grating removes the requirement. Experimental verification utilized white light for moiré interference of sensitivity 0.833 microm/fringe. Configurations readily amenable to compensation include moiré fringe multiplication by even factors and the minimum-deviation arrangement. Chromatic compensati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Optical Society of America A

سال: 1996

ISSN: 1084-7529,1520-8532

DOI: 10.1364/josaa.13.000832