Efficacy and feasibility of 226 Hz and 1000 Hz tympanometry in healthy pediatric patients

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-frequency (1000 Hz) tympanometry in normal neonates.

The characteristics of high frequency (1000 Hz) acoustic admittance results obtained from normal neonates were described in this study. Participants were 170 healthy neonates (96 boys and 74 girls) aged between 1 and 6 days (mean = 3.26 days, SD = 0.92). Transient evoked otoacoustic emissions (TEOAEs), and 226 Hz and 1000 Hz probe tone tympanograms were obtained from the participants using a Ma...

متن کامل

Tympanometry in Infants: A Study of the Sensitivity and Specificity of 226-Hz and 1,000-Hz Probe Tones

Introduction For infants under 6 months, the literature recommends 1,000-Hz tympanometry, which has a greater sensitivity for the correct identification of middle ear disorders in this population. Objective To systematically analyze national and international publications found in electronic databases that used tympanometry with 226-Hz and 1,000-Hz probe tones. Data Synthesis Initially, we iden...

متن کامل

Tympanometry with 226 and 1000 Hertz tone probes in infants.

UNLABELLED This study aimed at describing and analyzing tympanometric results obtained with 226 Hz and 1000 Hz probe tones; checking for correlations between tympanometry, otoacoustic emissions and otoscopic examination; describing abnormal results found in the evaluation procedures. METHODS Double-blind and prospective study. Our sample included 70 babies, between 7 days and one month and 13...

متن کامل

Measuring middle ear admittance in newborns using 1000 Hz tympanometry: a comparison of methodologies.

The present study aimed to compare three measures to estimate middle ear admittance in neonates using 1000 Hz tympanometry. Data were obtained from 36 full-term newborns, aged between 24 and 123 hours, who passed a transient evoked otoacoustic emissions test and assessed using a Madsen Otoflex impedance meter. The results showed that the mean middle ear admittances obtained by compensating for ...

متن کامل

Accoustic immitance measures in infants with 226 and 1000 hz probes : correlation with otoacoustic emissions and otoscopy examination Summary

Audi ological evaluation in infants should include the middle ear (immitance measures and otoscopy) and also a cochlear evaluation. Aim: To check which tympanometry tone test (226 Hz or 1000 Hz), transient otoacoustic emissions and otoscopy. Methods: Transient otoacoustic emissions were taken from sixty infants ranging from zero to four months of age. The babies were assigned to two groups of 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The European Research Journal

سال: 2020

ISSN: 2149-3189

DOI: 10.18621/eurj.488170