Effects of quadriceps angle on patellofemoral contact pressure
نویسندگان
چکیده
منابع مشابه
effect of quadriceps exercise training on muscle fiber angle in patients with patellofemoral pain syndrome
conclusions the study findings indicate that short-term exercises had no significant effect on the ratio of vmo to vl muscle fiber angles in patients with pfps. results there were no significant differences in the muscle strength and fiber angle of the vmo, vl oblique and longus muscles after training between the control and experimental groups (p > 0.05). patients and methods thirty-five subje...
متن کاملEffect of Quadriceps Exercise Training on Muscle Fiber Angle in Patients With Patellofemoral Pain Syndrome
Background: Imbalance between the vastus medialis oblique (VMO) muscle and the vastus lateralis oblique (VTO) Vastus lateralis has been thought to be a primary cause of abnormal patellar tracking, possibly leading to patellofemoral pain syndrome (PFPS). Objectives: The purpose of this study was to investigate the effect of quadriceps muscle strengthening exercises on the ratio of VMO to VL obli...
متن کاملContact pressure at osteochondral donor sites in the patellofemoral joint.
BACKGROUND The lowest contact pressure point is presumed to be the best site to harvest an osteochondral plug and minimize morbidity. HYPOTHESIS Patellofemoral contact pressures are not uniform and are lowest along the medial patellofemoral articulation. STUDY DESIGN Controlled laboratory study. METHODS Seven cadaveric knees were tested with an electroresistive, dynamic pressure sensor pl...
متن کاملReliability of Body Landmarks Analyzer for Measuring the Quadriceps Angle
Genovarum and Genovalgum are the most common postural deformities of the knee joint. A quadriceps angle is used to measure these anomalies. Methods of measuring this angle are divided into two categories: invasive and non-invasive. The purpose of the present research was to study the inter/intra rater reliability of the non-invasive Body Landmarks Analyzer method for measuring of the quadriceps...
متن کاملPatellofemoral contact pressures.
A test rig for studying the biomechanical behaviour of post-mortem human knees is built. For loading the quadriceps tendon a special clamping device is constructed, so the forces up to 3000 N could easily be transferred to the tendon. Several post-mortem human knees used in this study are tested to collect data about the general biomechanics of knee joint during squatting. The forces in the qua...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Veterinary Science
سال: 2020
ISSN: 1229-845X,1976-555X
DOI: 10.4142/jvs.2020.21.e69