Effectiveness of hand and Mtwo™ instruments in preparing oval-shaped root canals: in vitro study
نویسندگان
چکیده
منابع مشابه
effectiveness of hedstroum files and rotary k3 instruments in removal of obturation materials during retreatment in curved canals
چکیده ندارد.
15 صفحه اولComparison of Bacterial Leakage between 3 Different Root Canal Obturation Techniques in Oval Shaped Canals
Introduction: The purpose of this study was to evaluate the sealing ability of 3 obturation techniques in oval-shaped canals by bacterial leakage assessment. Methods: Sixty mandibular incisors with oval canals were selected after providing buccolingual and mesiodistal radiographs. The teeth were sectioned at a 10 mm distance from the apex. After instrumentation, the teeth were divided into 3 gr...
متن کاملPreparation of oval-shaped root canals in mandibular molars using nickel-titanium rotary instruments: a micro-computed tomography study.
INTRODUCTION This study evaluated the prepared surface areas of oval-shaped canals in distal roots of mandibular molars using four different instrumentation techniques. METHODS Teeth were prescanned and reconstructed using micro-computed tomography (MCT) scans at low resolution (68 microm). Forty-eight molars with ribbon-shaped/oval distal root canals were selected and randomly assigned to fo...
متن کاملCleaning efficiency of anatomic endodontic technology, ProFile System and Manual Instrumentation in oval-shaped root canals: an in vitro study.
AIM This in vitro study is an attempt to compare the effectiveness in cleaning oval shaped root canals using Anatomic Endodontic Technology (AET®), ProFile system® and Manual Instrumentation with K-files. METHODOLOGY Sixty oval shaped single rooted maxillary and mandibular premolars with straight canals were divided in to three groups. The root canals were, confirmed as being oval shape by me...
متن کاملEffectiveness in cleaning oval-shaped root canals using Anatomic Endodontic Technology, ProFile and manual instrumentation: a scanning electron microscopic study.
AIM To compare in vitro the cleanliness of root canal walls in oval-shaped root canals following automated or manual instrumentation. METHODOLOGY Forty-five oval-shaped single-rooted maxillary and mandibular premolars with straight canals were divided into three groups of 15. Automated canal preparation was performed using Anatomic Endodontic Technology (AET, group 1) and the ProFile system (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Revista da Faculdade de Odontologia - UPF
سال: 2016
ISSN: 2318-843X,1413-4012
DOI: 10.5335/rfo.v21i2.5322