Effectiveness of abdominal shields in chest radiography: a Monte Carlo evaluation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Measurement of organ dose in chest CT examination using Monte Carlo simulation

Background: Exposure conditions in CT examinations are quite different from conventional Xray. In CT examination higher dose is given to patient in comparison with the dose in other diagnostic examinations. In order to calculate organ effective dose in chest CT, Monte Carlo simulation has been used in this study. Materials and Methods: The Impact survey data were used to determine the ...

متن کامل

Evaluation Evaluation a Monte Carlo study

Over the last decade there has been increasing concern about the biases embodied in traditional evaluation methods for Natural Language Processing/Learning, particularly methods borrowed from Information Retrieval. Without knowledge of the Bias and Prevalence of the contingency being tested, or equivalently the expectation due to chance, the simple conditional probabilities Recall, Precision an...

متن کامل

Monte Carlo Simulation of Scattering Phenomenon Effects on Industrial Radiography

As x or gamma rays pass through different materials, some of the photons interact with the matter and their energy can be absorbed or scattered. Scattering is the main factor of reducing the sensitivity of radiographs in industrial and also medical radiography. One way to determine the accuracy of the experiments and the sensitivity of those experimental determinations of μ to scatter and colli...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The British Journal of Radiology

سال: 2016

ISSN: 0007-1285,1748-880X

DOI: 10.1259/bjr.20160465