Effective Semiactive Base Isolation System under Multiple Earthquakes
نویسندگان
چکیده
منابع مشابه
OPTIMAL SMART BASE ISOLATION SYSTEM FOR MULTIPLE EARTHQUAKES
Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, ...
متن کاملMULTI-OBJECTIVE SEMI-ACTIVE BASE ISOLATION SYSTEM
Semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. In this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (MR) damper has been studied for co...
متن کاملPillow-Shape Base Isolation System and Its Seismic Behavior
In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two ...
متن کاملTHE CAPABILITY OF OPTIMAL SINGLE AND MULTIPLE TUNED MASS DAMPERS UNDER MULTIPLE EARTHQUAKES
The main focus of this research has been to investigate the effectiveness of optimal single and multiple Tuned Mass Dampers (TMDs) under different ground motions as well as to develop a procedure for designing TMD and MTMDs to be effective under multiple records. To determine the parameters of TMD and MTMDs under multiple records various scenarios have been suggested and their efficiency has be...
متن کاملmulti-objective semi-active base isolation system
semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. in this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (mr) damper has been studied for co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Advances in Civil Engineering
سال: 2018
ISSN: 1687-8086,1687-8094
DOI: 10.1155/2018/7382481