Effect of Steam Curing on Concrete Piles with Silica Fume
نویسندگان
چکیده
منابع مشابه
The Effect of Recurring on Physical Properties of Concrete Containing Silica-Fume with Improper First Curing
As regards if curing stops for some time and then resumes again, then strength gain will also stop and reactive, in this study with choose suitable curing conditions after improper first curing (recurring) for normal and silica-fume concrete, Effect of this curing conditions on strength and permeability was investigated. The results from tests such as compressive strength, capillary water absor...
متن کاملthe effect of recurring on physical properties of concrete containing silica-fume with improper first curing
as regards if curing stops for some time and then resumes again, then strength gain will also stop and reactive, in this study with choose suitable curing conditions after improper first curing (recurring) for normal and silica-fume concrete, effect of this curing conditions on strength and permeability was investigated. the results from tests such as compressive strength, capillary water absor...
متن کاملInfluence of Silica Fume on Normal Concrete
The incorporation of silica fume into the normal concrete is a routine one in the present days to produce the tailor made high strength and high performance concrete. The design parameters are increasing with the incorporation of silica fume in conventional concrete and the mix proportioning is becoming complex. The main objective of this paper has been made to investigate the different mechani...
متن کاملEffects of Silica Fume in Conventional Concrete
The production of tailor made high strength and high performance concrete are made by incorporating silica fume into the normal concrete and it is a routine one in the present days. The mix proportioning is intricate and the design parameters are increased due to the incorporation of silica fume in conventional concrete. The aim of this paper is to look into the different mechanical properties ...
متن کاملInfluence of Silica Fume on Chloride Resistance of Concrete
A series of concrete slabs were cast with 0, 7, and 12% by mass silica fume replacement of cement at W/CM = 0.35, 0.40, and 0.45. After either moist or steam curing, a variety of chloride resistance tests were performed. These included AASHTO T259, modified T259, T277, as well as several bulk diffusion tests and sorptivity tests. Results indicate that the use of properly dispersed silica fume r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Concrete Structures and Materials
سال: 2010
ISSN: 1976-0485
DOI: 10.4334/ijcsm.2010.4.1.009