Seismic behavior of drilled beam section in moment connections
Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...
متن کاملPushover Analysis of Steel Seismic Resistant Frames with Reduced Web Section and Reduced Beam Section Connections
The widespread brittle failure of welded beam-to-column connections caused by the 1994 Northridge and 1995 Kobe earthquakes highlighted the need for retrofitting measures effective in reducing the strength demand imposed on connections under cyclic loading. Researchers presented the reduced beam section (RBS) as a viable option to create a weak zone away from the connection, aiding the preventi...
متن کاملModeling Steel Frame Buildings in Three Dimensions. I: Panel Zone and Plastic Hinge Beam Elements
A procedure for efficient three-dimensional nonlinear time-history analysis of steel framed buildings is derived. It incorporates two types of nonlinear beam elements—the plastic hinge type and the elastofiber type—and nonlinear panel zone elements to model yielding and strain-hardening in moment-frames. Floors and roofs of buildings are modeled using 4-node elastic diaphragm elements. The proc...
متن کاملThe Effect of the Slot Length on Beam Vertical Shear in I-Beams with Moment Connections
This paper evaluates the effect of slot existence with limited length between flanges and web junction of I-shaped beams at the region of moment connections on vertical force and shear stress distribution in beam flanges and web at connection section in comparison with classical theory of stress distribution. The main purpose of this research is to evaluate the efficiency of the slot in connect...
متن کاملEVALUATION THE EFFECT OF STRONG COLUMN-WEAK BEAM RATIO ON SEISMIC PERFORMANCE OF OPTIMALLY DESIGNED STEEL MOMENT FRAMES
The present work is aimed at assessing the impact of strong column-weak beam (SCWB) criterion on seismic performance of optimally designed steel moment frames. To this end, different SCWB ratios are considered for steel special moment resisting frame (SMRF) structures and performance-based design optimization process is implemented with the aid of an efficient metaheuristic. The seismic collaps...