Effect of outlet location on indoor air quality for stratum ventilation under heating mode
نویسندگان
چکیده
Warm air supply is widely used to condition indoor environment in winter. It has been proved that stratum ventilation (SV), as a novel distribution, potentials be applied for heating. The outlet location may affect quality (IAQ) due interaction between thermal plumes from heat sources and room airflows. In this study, the effect of on IAQ SV was investigated 9 cases under heating mode. outlets were located at heights 0.4 m same side wall inlet, 0.4, 1.3 opposite wall, respectively. concentration carbon dioxide measured an experimental chamber with dimensions 5850 mm(L) × 5057 mm(W) 2554 mm(H). average removal efficiency ( ε CRE ) evaluation indexes. results showed breathing zone inlet lower than those wall. At scenario, greater one, showing good performance.
منابع مشابه
Indoor air quality and ventilation strategies in the use of combustion space heating appliances in housing.
Indoor air quality (IAQ) in the use of combustion appliances is important for adequate evaluation of air pollution health risks. Since people spend most of their time inside buildings, especially the elderly and children, their exposure to indoor air contaminants can increase health problems in the community. Combustion materials emitted from combustion space heating appliances in housing durin...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولVentilation Positive Pressure Intervention Effect on Indoor Air Quality in a School Building with Moisture Problems
This case study investigates the effects of ventilation intervention on measured and perceived indoor air quality (IAQ) in a repaired school where occupants reported IAQ problems. Occupants' symptoms were suspected to be related to the impurities leaked indoors through the building envelope. The study's aim was to determine whether a positive pressure of 5-7 Pa prevents the infiltration of harm...
متن کاملNumerical Study Of The Effect Of Air Terminal Layouts On The Performance Of Stratum Ventilation System
It has been found that air terminal layouts could affect ventilation performance in a room. As a new air distribution system, stratum ventilation was proposed to accommodate elevated room temperatures. Its performance with various air terminal layouts was investigated by numerical method in this research. Totally four different exhausts locations were studied to determine the optimal exhaust lo...
متن کاملTranspired solar collectors for ventilation air heating
g1 Richard Hall MEng, AIEMA EngD Researcher, Steel Construction Institute, Surrey EngD in Environmental Technology, University of Surrey, Guildford, UK g2 Xiaoxin Wang MSc, PhD Research Fellow, Oxford Institute for Sustainable Development, Oxford Brookes University, Oxford, UK g3 Raymond Ogden DiplArch, PhD Professor, Oxford Institute for Sustainable Development, Oxford Brookes University, Oxfo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2022
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202235605034