Effect of liquid depth, column inclination and baffle plates on gas holdup in bubble columns.
نویسندگان
چکیده
منابع مشابه
Eulerian simulation of bubble columns reactors and effect of various parameters on the gas holdup
Gas holdup and bubble size are important parameters for simulation and designing in bubble column reactors. Because based on these parameters, the available gas-liquid interfacial area is defined for mass transfer. In this paper, the results of applying magnetic fields on the velocity field and volume fraction of gas holdup are reported. Hydrodynamics of the bubble column in the reactors is inv...
متن کاملGas holdup in a gas-liquid-fiber semi-batch bubble column
A 4-m high, 15.24-cm diameter semi-batch bubble column connected to one of three perforated plate gas distributors with open area ratios A = 0.57%, 0.99%, and 2.14% is employed to study gas holdup and flow regime in Rayon and Nylon fiber suspensions. This study determines the effect of superficial gas velocity, fiber type, fiber mass fraction, fiber length, and aeration plate open area ratio on...
متن کاملGas-liquid Flow in a Rectangular Partially Aerated Bubble Column: Combined Effect of Aspect Ratio and Superficial Gas Velocity
Bubble columns are multiphase equipments used to bring into contact gas and liquid phases. Gas, that constitutes the dispersed phase, is distributed at the bottom of the column and rises as bubbles through the liquid that constitutes the continuous phase. They are frequently used in the industry although the partial knowledge of the fluid dynamics of the gas-liquid flow have hindered a complete...
متن کاملInteractional effects of bubble size, particle size, and collector dosage on bubble loading in column flotation
The success of flotation operation depends upon the thriving interactions of chemical and physical variables. In this work, the effects of particle size, bubble size, and collector dosage on the bubble loading in a continuous flotation column were investigated. In other words, this work was mainly concerned with the evaluation of the true flotation response to the changes in the operating varia...
متن کاملthe effect of oxytetracycline on serum calcium, phosphorus and magnesium in cattle
نتایج این مطالعه نشان می دهد که مقدار کلسیم (یونیزه و تام)، منیزیم و فسفر به طور معنی داری تغییر پیدا کرد به جزء مقدار کلسیم تام و منیزیم در روش داخل عضلانی که تغییر معنی داری نداشته است. بر اساس نتایج این مطالعه می توان نتیجه گیری کرد که اکسی تتراساکلین بر روی مقادیر سرمی کلسیم و منیزیم تأثیر می گذارد باید مقدار این کاتیون ها در بیماران، در هنگامی که اکسی تتراسایکلین استفاده می شود مورد توجه ق...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JOURNAL OF CHEMICAL ENGINEERING OF JAPAN
سال: 1985
ISSN: 0021-9592,1881-1299
DOI: 10.1252/jcej.18.349