Effect of gas-liquid flow mode and column diameter on gas holdup and gas-liquid interfacial area in bubble column.
نویسندگان
چکیده
منابع مشابه
Gas holdup in a gas-liquid-fiber semi-batch bubble column
A 4-m high, 15.24-cm diameter semi-batch bubble column connected to one of three perforated plate gas distributors with open area ratios A = 0.57%, 0.99%, and 2.14% is employed to study gas holdup and flow regime in Rayon and Nylon fiber suspensions. This study determines the effect of superficial gas velocity, fiber type, fiber mass fraction, fiber length, and aeration plate open area ratio on...
متن کاملGas-liquid Flow in a Rectangular Partially Aerated Bubble Column: Combined Effect of Aspect Ratio and Superficial Gas Velocity
Bubble columns are multiphase equipments used to bring into contact gas and liquid phases. Gas, that constitutes the dispersed phase, is distributed at the bottom of the column and rises as bubbles through the liquid that constitutes the continuous phase. They are frequently used in the industry although the partial knowledge of the fluid dynamics of the gas-liquid flow have hindered a complete...
متن کاملLarge Eddy Simulation of the Gas-Liquid Flow in a Square Cross-sectioned Bubble Column
Column N.G. Deen, T. Solberg and B.H. Hjertager Chem. Eng. Lab., Aalborg Univ. Esbjerg; Niels Bohrs Vej 8; DK-6700 Esbjerg; Denmark Abstract In this work the use of large eddy simulations (LES) in numerical simulations of the gas-liquid flow in bubble columns is studied. The Euler-Euler approach is used to describe the equations of motion of the two-phase flow. It is found that, when the drag, ...
متن کاملGas-Liquid Interfacial Area, Bubble Size and Liquid-Phase Mass Transfer Coefficient in a Three-Phase External Loop Airlift Bubble Column
The interfacial area a was measured by the sulfite oxidation method in a three-phase external loop airlift bubble column suspending completely the different concentrations of ion exchange resin particles in aqueous carboxymethyl cellulose (CMC) solutions with a wide range of viscosity. The column had been previously studied for the circulating liquid velocity UL, gas holdup G and volumetric gas...
متن کاملEulerian simulation of bubble columns reactors and effect of various parameters on the gas holdup
Gas holdup and bubble size are important parameters for simulation and designing in bubble column reactors. Because based on these parameters, the available gas-liquid interfacial area is defined for mass transfer. In this paper, the results of applying magnetic fields on the velocity field and volume fraction of gas holdup are reported. Hydrodynamics of the bubble column in the reactors is inv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: KAGAKU KOGAKU RONBUNSHU
سال: 1988
ISSN: 0386-216X,1349-9203
DOI: 10.1252/kakoronbunshu.14.182