Effect of Endocervical Specimen Adequacy on Ligase Chain Reaction Detection of Chlamydia trachomatis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of endocervical specimen adequacy on ligase chain reaction detection of Chlamydia trachomatis.

Several studies have demonstrated that the sensitivity of a commercially available PCR test for the detection of Chlamydia trachomatis (Roche Diagnostics) is affected by the cellular quality of the endocervical swab specimens. The cellular adequacies of 1,633 female endocervical swab specimens were assessed and compared with the results of C. trachomatis detection obtained by ligase chain react...

متن کامل

Effect of endocervical-specimen adequacy on detection of Chlamydia trachomatis by the APTIMA COMBO 2 assay.

Six hundred one endocervical specimens were analyzed for Chlamydia trachomatis by the APTIMA Combo 2 assay and evaluated for columnar epithelial cell adequacy by direct fluorescent-antibody staining. With 5.5% positive adequate and 7.8% positive inadequate specimens (P=0.27), the study suggested no difference in positivity rates due to specimen adequacy when this amplified technology was used.

متن کامل

Detection of Chlamydia trachomatis endocervical infections by ligase chain reaction versus ACCESS Chlamydia antigen assay.

Ligase chain reaction (LCR) was compared with ACCESS immunoassay for detection of chlamydial infections in females. Despite efforts to improve ACCESS performance by evaluation of specimens that were in the test performance "grey zone," LCR remained more sensitive and was less expensive to perform. ACCESS had a sensitivity of 83.9%, a specificity of 99.7%, a positive predictive value of 96.3%, a...

متن کامل

A comparison of ligase chain reaction to polymerase chain reaction in the detection of Chlamydia trachomatis endocervical infections.

OBJECTIVE To compare the reliability of ligase chain reaction (LCR) to polymerase chain reaction (PCR) in detecting Chlamydia trachomatis endocervical infections. METHODS We conducted a prospective study of 486 patients at risk for chlamydial infection of the endocervix. We obtained two endocervical specimens from each patient and used LCR and PCR to detect C. trachomatis. Discrepant results ...

متن کامل

Influence of endocervical specimen adequacy on PCR and direct fluorescent-antibody staining for detection of Chlamydia trachomatis infections.

The cellular quality of the endocervical swab specimen used for the detection of Chlamydia trachomatis may dramatically impact the sensitivity of the diagnostic assay used. An evaluation of the adequacy of 319 endocervical swab specimens from women attending two inner-city sexually transmitted disease and family planning clinics, as well as five high school-based family planning clinics, was pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Clinical Microbiology

سال: 2001

ISSN: 0095-1137,1098-660X

DOI: 10.1128/jcm.39.11.3838-3841.2001