Effect of Droplet Diameter on Liquid Impingement Erosion
نویسندگان
چکیده
منابع مشابه
Comparison of cavitation erosion rate with liquid impingement erosion rate
Both cavitation erosion and liquid impingement erosion are phenomena that can cause pipe wall thinning in power plants. The Code for Power Generation Facilities, Rules on Pipe Wall Thinning Management, was published by the JSME (Japan Society of Mechanical Engineers) in 2005. The code says that cavitation erosion shall be prevented either in the design stage or by daily inspection. On the other...
متن کاملAssessing Liquid Droplet Erosion Potential in Centrifugal Compressor Impellers
This paper presents a method for estimating the potential for liquid droplet erosion in compression system components, such as the impeller of centrifugal compressors. The erosion model selected is used to calculate a threshold velocity that represents the limit for the onset of erosion damage. The parameters used in the model include the liquid phase density and viscosity, impeller geometry, s...
متن کاملeffect of oral presentation on development of l2 learners grammar
this experimental study has been conducted to test the effect of oral presentation on the development of l2 learners grammar. but this oral presentation is not merely a deductive instruction of grammatical points, in this presentation two hypotheses of krashen (input and low filter hypotheses), stevicks viewpoints on grammar explanation and correction and widdowsons opinion on limited use of l1...
15 صفحه اولWater Impingement Erosion of Deep-Rolled Ti64
In this work, the Liquid Impingement Erosion (LIE) performances of deep-rolling (DR) treated and non-treated Ti64 were investigated. Various erosion stages, from the incubation to the terminal erosion stages, could be observed. A full factorial design of experiments was used to study the effect of DR process parameters (Feed Rate, Spindle Velocity, Number of Passes, Pressure) on the residual st...
متن کاملObservations of droplet impingement on a ceramic porous surface
The dynamic aspects of droplet impingement on a porous ceramic surface were studied experimentally. Single-shot flash photography was used to photographically record the deformation and spreading on the surface. The observations were made with ambient pressure (0.10 MPa), ambient temperature (cu. 22”C), initial droplet diameter (1.5 mm), and the impact Weber number (43) fixed. The primary param...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series A
سال: 2011
ISSN: 0387-5008,1884-8338
DOI: 10.1299/kikaia.77.1760