abstract in a protocol analysis of second language writing from 20 adult english as a foreign language (efl) iranian students, this research observed how language-switching (l-s), i.e., first language use in l2 writing, was affected by l2 proficiency. switching interactively between first (l1) and second (l2) languages has been recognized as one of the salient characteristics of l2 writing....
15 صفحه اولEstimation of New Weighted Controlled Switching Overvoltage by RBFN Model
Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate works on electromagnetic transients are considered in the process of designing transmission systems, such works are not prevalent in day-to-da...
متن کاملHigh Voltage Surge Arresters for Protection of Series Compensation and HVDC Converter Stations
The efficiency of overhead power lines can be increased by series compensation or HVDC transmission. These complex systems can be protected from overvoltages by metal oxide surge arresters. Both porcelain and polymer tube design surge arresters are used for these applications, however, polymer tube design surge arresters offer various advantages over porcelain arresters such as light weight, ex...
متن کاملthe washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests
در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است
15 صفحه اولStudy on Very Fast Transient Overvoltage of Closing No-load China UHV Transmission Demonstration Project Jindongnan-Nanyang- Jingmen 1000 kV Transmission Lines
When the ultra high voltage (UHV) substation used the gas insulated switchgear (GIS) system to switch lines with capacitive current, the pre-breakdown and multiple reignition will occur between switching contacts. Because of discharge characteristics of SF6 and special structures of GIS system, the variations of the electromagnetic transient process and very fast transient overvoltage (VFTO) ar...