Effect of dedicated mechanical subcooler size and gas cooler pressure control on transcritical CO2 booster systems
نویسندگان
چکیده
• Mechanical subcooling increases the COP of CO 2 systems at high outdoor temperature. The gas cooler pressure plants can be reduced with degree. Optimum degree and optimum cooling capacity subcooler are found. Dedicated Subcooling (DMS) is one most investigated effective strategies applied to increase performance commercial refrigeration in transcritical operation. Further benefits obtained by a reduction main cycle conditions. In this work important parameters for design operation such system, i.e. DMS capacity, pressure, considered their effect on annual energy use plant estimated warm hot climate conditions means validated model. also compared parallel compression scheme performed through water chiller dedicated HVAC. results solution among those investigated, choice best operating allows further saving cost reduction.
منابع مشابه
Effect of CO2 Concentration in Injecting Gas on Minimum Miscibility Pressure: Compositional Model and Experimental Study
For technical and economic success of miscible gas injection projects, an accurate laboratory measurement of Minimum Miscibility Pressure (MMP) at reservoir conditions is essential. On the other hand, compositional reservoir simulator is a useful tool in gas injection studies and prediction of MMP. The main goal of this paper is to describe a procedure to generate a three phase sequential t...
متن کاملeffect of seed priming and irrigation regimes on yield,yield components and quality of safflowers cultivars
این مطالعه در سال 1386-87 در آزمایشگاه و مزرعه پژوهشی دانشگاه صنعتی اصفهان به منظور تعیین مناسب ترین تیمار بذری و ارزیابی اثر پرایمینگ بر روی سه رقم گلرنگ تحت سه رژیم آبیاری انجام گرفت. برخی از مطالعات اثرات سودمند پرایمینگ بذر را بر روی گیاهان مختلف بررسی کرده اند اما در حال حاضر اطلاعات کمی در مورد خصوصیات مربوط به جوانه زنی، مراحل نموی، عملکرد و خصوصیات کمی و کیفی بذور تیمار شده ژنوتیپ های م...
Effect of Internal Heat Exchanger on Performance of Transcritical CO2 Systems with Ejector
The objective of this paper is to explore whether the use of an internal heat exchanger can further improve the performance of transcritical ejector systems with C02 as the working fluid. Instead of using a simplified thermodynamic cycle analysis, the approach taken here is based on a more elaborated and experimentally validated system model for a real mobile air-conditioning system for a typic...
متن کاملthe effect of explicit teaching of metacognitive vocabulary learning strategies on recall and retention of idioms
چکیده ندارد.
15 صفحه اولField Evaluation for Air-source Transcritical CO2 Heat Pump Water Heater with Optimal Pressure Control
Several optimal discharge pressure correlations for transcritical CO2 heat pump in literature have been discussed in this paper. Most of them are related to the ambient temperature, the evaporation temperature and the gas cooler outlet temperature. A revised optimal discharge pressure model as the function of ambient temperature and water outlet temperature is developed based on earlier experim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Thermal Engineering
سال: 2021
ISSN: ['1873-5606', '1359-4311']
DOI: https://doi.org/10.1016/j.applthermaleng.2020.116145