Effect of anaerobic bout using wingate cycle ergometer on pressure pain threshold in normal individuals
نویسندگان
چکیده
منابع مشابه
Analysis of anaerobic capacity in rowers using Wingate test on cycle and rowing ergometer.
The 30-s all-out Wingate test has been used in athletes of all sport specialties to measure the capacity for short duration, high power output while cycling. The aim of this study was to establish differences in measuring anaerobic capacity between the classic Wingate test on a cycling ergometer and the modified Wingate test on a rowing ergometer in rowers. A group of20 rowers was tested by bot...
متن کاملReliability of the Wingate Anaerobic Test with Ice Hockey Players on the Velotron Cycle Ergometer
Purpose: This study evaluated the test-retest reliability of the Wingate Anaerobic Test (WAnT) performed on a Velotron electromagnetically-braked cycle ergometer (EE) for powertrained athletes and assessed whether a familiarization trial was necessary to achieve high test-retest reliability. Methods: Twentyone male ice hockey players (age 23.5 ± 4.7 yrs, mass 86.3 ± 16.6 kg, height 180.9 ± 7.4 ...
متن کاملthe effect of aqueous extract of garlic on formalin-induced pain in male rats
چکیده اثر عصاره آبی سیر بر درد ناشی از آزمون فرمالین در موش صحرایی نر به کوشش نرگس اسکندری روزبهانی زمینه و هدف: گیاه سیر از خانواده لیلیاسه و گونهallium sativum بومی آسیای میانه بوده و از دوران ،باستان تاکنون به خواص درمانی متفاوت آن مثل: کاهندگی قندخون، کلسترول خون، فشار خون، اثرات مفیدآن بر دستگاه قلبی عروقی و بیماریهای انعقادی خون، اثرات آنتی اکسیداتیو، درمان بیماریهای تنفسی وگوارشی، ا...
15 صفحه اولThe effect of low power LASER acupuncture on experimental pain threshold in normal subjects
Background: Acupuncture is an indispensable part of traditional Chinese medicine for relief of pain. The purpose of this study was the immediate & latent of low power LASER Ga-Al-As irradiation applied to acupuncture points on experimental pain threshold. Methods: This quasi-experimental study was conducted on seventy adult women ranging from 20 to 40 years old assigned randomly into two groups...
متن کاملReliability of a 2-bout exercise test on a wattbike cycle ergometer.
PURPOSE To determine the intraday and interday reliability of a 2 × 4-min performance test on a cycle ergometer (Wattbike) separated by 30 min of passive recovery (2 × 4MMP). METHODS Twelve highly trained cyclists (mean ± SD; age = 20 ± 2 y, predicted VO2max = 59.0 ± 3.6 mL · kg-1 · min-1) completed six 2 × 4MMP cycling tests on a Wattbike ergometer separated by 7 d. Mean power was measured t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Pain
سال: 2017
ISSN: 0970-5333
DOI: 10.4103/ijpn.ijpn_70_16