Echo time optimization for linear combination myelin imaging

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echo time optimization for linear combination myelin imaging.

A 3-echo linear combination myelin imaging method is presented. The echo times and weights are chosen such that the signal-to-noise ratio (SNR) of myelin-water is maximized, and signals from other white matter components are sufficiently suppressed. Interfering tissue water and cerebrospinal fluid (CSF) signals are much stronger than myelin due to their longer T2 and abundance. By carefully opt...

متن کامل

Physiological noise compensation in gradient-echo myelin water imaging

In MRI, physiological noise which originates from cardiac and respiratory functions can induce substantial errors in detecting small signals in the brain. In this work, we explored the effects of the physiological noise and their compensation methods in gradient-echo myelin water imaging (GRE-MWI). To reduce the cardiac function induced inflow noise, flow saturation RF pulses were applied to th...

متن کامل

Short echo time MR spectroscopic imaging for neonatal pediatric imaging.

A short echo time (30 milliseconds) MR spectroscopic imaging pulse sequence was implemented for applications of neonatal brain imaging. Multiple spatial saturation bands were used to eliminate strong signals originating from the subcutaneous lipids to enable volumetric region coverage. Metabolite signal intensity-to-noise ratio < or =40 was acquired in 9 minutes of scan time over an 8 x 8 x 8 s...

متن کامل

Optimization of gray/white matter contrast with fast inversion recovery for myelin suppression: a comparison of fast spin-echo and echo-planar MR imaging sequences.

We compared two MR imaging sequences, fast inversion recovery for myelin suppression (FIRMS) and echo-planar FIRMS (EP-FIRMS), for depicting gray/white matter contrast. In 18 patients, the frequency bandwidth (BW) was optimized for each sequence; in nine patients, the BW was held constant. In the BW-optimized group, the mean contrast-to-noise ratio (C/N) was three times higher with the FIRMS se...

متن کامل

48 echo T2 myelin imaging of white matter in first-episode schizophrenia: Evidence for aberrant myelination

Myelin water imaging provides a novel strategy to assess myelin integrity and corresponding clinical relationships in psychosis, of particular relevance in frontal white matter regions. In the current study, T2 myelin water imaging was used to assess the myelin water fraction (MWF) signal from frontal areas in a sample of 58 individuals experiencing first-episode psychosis (FEP) and 44 healthy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2005

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.20360