Easy Measurement System for Two Dimensional Relative Dose Distribution of Ion Beam Using Gaf-chromic Film and Image Scanner
نویسندگان
چکیده
منابع مشابه
Measurement Of Scatter Factors For Small Photon Fields Using Gaf chromic EBT2 Film
Introduction: Small field dosimetry is challenging for radiotherapy dosimetry. measurement of the output factor in the air and water (Sc, Scp) is one of the input parameters for commissioning of treatment planning systems and beam modeling. The aims of this study are to measured Sc,Scp for small fields with EBT2 and Ion chamber and design a appropriate mini-phantom for small fi...
متن کاملارزیابی تغییرات توزیع دز در مقطع نگاری کامپیوتری با تغییر موازی سازی با استفاده از فیلم EBT و فانتوم PMMA
X-ray computed tomography is an imaging method which makes tomographic images with high contrast and resolution. However, CT-scans deliver much more radiation dose compared with other imaging techniques. The aim of this study was to evaluate two-dimensional dose distribution in a PMMA phantom as well as investigationof the effect ofcollimation factor on the dose distribution measuredusing GAF-C...
متن کاملA new method for ideal dose distribution of two adjacent fields for external beam radiation therapy
Abstract Background: Adjacent treatment fields are commonly used in external beam radiation therapy, such as mantle and inverted-Y fields for the treatment of Hodgkin’s disease and craniospinal fields used in the treatment of medulloblastoma and head and neck tumors when the lateral neck fields are placed adjacent to the anterior supraclavicular field. In each of these situations, there is a p...
متن کاملDose Distribution Evaluation and Independent Quality Check of Spherical INTRABEAM™ Applicators via Radiochromic EBT2 Film Measurement
Introduction: The present study was conducted to implement a simple practical independent quality check of depth dose and isotropy of the Intrabeam™ therapeutic X-ray machine using radiochromic EBT2 film. Material and Methods: Theindependent quality check of 1.5, 3.5, and 5-cm spherical Intrabeam™ applicators was accomplished using particular EBT2 film cutting pieces with internal rounded edge...
متن کاملStatus of two-dimensional ion velocity measurement system in NSTX
A two-dimensional ion velocity measurement system is being developed under a US-JAPAN collaborative activity. The diagnostic is used to determine Doppler shifts from the intensity ratio of a visible line from the same light source, measured with two interference filters that have different transmission pass bands. A fast visible camera is used as two-dimensional detector. The system was tested ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 2008
ISSN: 0033-8303
DOI: 10.3769/radioisotopes.57.87