Easy and direct method for calibrating atomic force microscopy lateral force measurements

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Atomic Force Microscopy and Direct Surface Force Measurements

The atomic force microscope (AFM) is designed to provide high-resolution (in the ideal case, atomic) topographical analysis, applicable to both conducting and nonconducting surfaces. The basic imaging principle is very simple: a sample attached to a piezoelectric positioner is rastered beneath a sharp tip attached to a sensitive cantilever spring. Undulations in the surface lead to deflection o...

متن کامل

Calibration of lateral force measurements in atomic force microscopy with a piezoresistive force sensor.

We present here a method to calibrate the lateral force in the atomic force microscope. This method makes use of an accurately calibrated force sensor composed of a tipless piezoresistive cantilever and corresponding signal amplifying and processing electronics. Two ways of force loading with different loading points were compared by scanning the top and side edges of the piezoresistive cantile...

متن کامل

Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization

Proper force calibration is a critical step in atomic and lateral force microscopies (AFM/LFM). The recently published torsional Sader method [C. P. Green et al., Rev. Sci. Instrum. 75, 1988 (2004)] facilitates the calculation of torsional spring constants of rectangular AFM cantilevers by eliminating the need to obtain information or make assumptions regarding the cantilever's material propert...

متن کامل

Direct force measurements between carboxylate - modified latex microspheres and glass using atomic force microscopy

9 Depths of colloid-surface interaction energy minima have been sometimes utilized for estimation of the force holding a colloid to the surface upon contact. Since this approach assumes that non-contact forces prevail following attachment, a comparison of this approach to direct measurement via atomic force microscopy is warranted. Interaction and adhesion forces between 1.0m diameter carboxyla...

متن کامل

Direct Force Measurement of Liposomes by Atomic Force Microscopy

Liposomes serve as models for cells and show increasing applications in medical and nonmedical fields. Unilamellar vesicles are prepared from multilamellar vesicle (MLV) dispersions either by sonication or extrusion. The shape stability of liposomes is important in the understanding of membrane fusion, as well as in drug delivery and gene therapy. Therefore it has been the subject of numerous t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2007

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.2745733