Early Wrist Mobilization After Distal Radius Fractures Stabilized by Volar Locking Plate

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Residual wrist pain after volar locking plate fixation of distal radius fractures.

A prospective multicenter clinical study evaluated, using the Hand20 and hand diagram, the disability, incidence, location, and predictive factors of residual wrist pain 18 months after volar locking plate fixation of distal radius fracture in 122 patients. The average Hand20 score and numeric rating scores for pain were 13.1 +/- 18.2 and 2.1 +/- 23, respectively. Fifty-seven patients indicated...

متن کامل

Volar plate fixation of distal radius fractures.

Volar fixed angle fixation may be considered as the beginning of a new era in restoring wrist function to patients with dorsally displaced distal radius fractures even in the face of comminuted or osteopenic bone. A thorough understanding of the anatomy of the wrist is a prerequisite when volarly approaching dorsally displaced distal radius fractures. The demonstration of the device theoretical...

متن کامل

Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report

We describe a 59-year-old man who had nonunion of a right distal radius fracture after volar locking plate fixation. He underwent open reduction and internal fixation with a volar locking plate system for a dorsally displaced, unstable distal radius fracture at a previous hospital 5 months ago. Radiographs of the injured wrist showed nonunion of the distal radius with 1.5-mm ulnar minus varianc...

متن کامل

Complications of Distal Radius Fractures Treated by Volar Locking Plate Fixation.

The current study investigated the incidence of complications after surgery for distal radial fractures. This multicenter retrospective study was conducted at 11 institutions. A total of 824 patients who had distal radius fractures that were treated surgically between January 2010 and August 2012 were identified. The study patients were older than 18 years and were observed for at least 12 week...

متن کامل

Mechanical failure of the distal radius volar locking plate.

PURPOSE To review 9 cases of mechanical failure of the volar locking plate for distal radial fractures. METHODS Records of 374 consecutive patients who underwent volar locking plating for distal radial fractures were reviewed. Mechanical failures of the volar locking plate were defined as plate breakage or bending, screw breakage or loosening, or collapse of articular fragments resulting in i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: HAND

سال: 2016

ISSN: 1558-9447,1558-9455

DOI: 10.1177/1558944716660555be