Dynamics of tidal volume and ventilation heterogeneity under pressure-controlled ventilation during bronchoconstriction: a simulation study.

The difference in effectiveness between volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) on mechanically ventilated patients during bronchoconstriction is not totally clear. PCV is thought to deliver a more uniform distribution of ventilation than VCV, but the delivered tidal volume could be unstable and affected by changes in the degree of constriction. To explore ...

متن کامل

Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...

متن کامل

Inspiratory time and tidal volume during intermittent positive pressure ventilation.

We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.

متن کامل

Delivery of tidal volume from four anaesthesia ventilators during volume-controlled ventilation: a bench study.

BACKGROUND Tidal volume (V(T)) must be accurately delivered by anaesthesia ventilators in the volume-controlled ventilation mode in order for lung protective ventilation to be effective. However, the impact of fresh gas flow (FGF) and lung mechanics on delivery of V(T) by the newest anaesthesia ventilators has not been reported. METHODS We measured delivered V(T) (V(TI)) from four anaesthesia...

متن کامل

Volume-controlled versus pressure-controlled ventilation-volume guaranteed mode during one-lung ventilation

BACKGROUND The purpose of this study was to investigate the changes in airway pressure and arterial oxygenation between ventilation modes during one-lung ventilation (OLV) in patients undergoing thoracic surgery. METHODS We enrolled 27 patients for thoracic surgery with OLV in the lateral decubitus position. The subjects received various modes of ventilation in random sequences during surgery...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Physiology

سال: 2010

ISSN: 8750-7587,1522-1601

DOI: 10.1152/japplphysiol.01401.2009