Lanthanum(III) Ion Selective Electrode Based on a New Ionophore

A PVC membrane electrode based on 1-[({[(butylsulfunyl)carbothioyl]disulfanyl} carbothioyl)sulfanyl]butane as a suitable ion carrier for determination of lanthanum(III) ion was prepared. This electrode revealedsuch a good selectivity toward La3+ ion over a wide variety of other metal ions. Some experimental parametersuch as membrane composition, nature, and amount of plasticizer, the amount of ...

متن کامل

Chromium (III) ion selective electrode based on di(benzylamino)glyoxime

A new poly(vinylchloride) membrane sensor for Cr3+ ions based on di (benzylamino)glyoxime asan ionophore was prepared. The electrode has a linear dynamic range 1×10-6-1×10-1 mol l-1,with aNernstian slope of 20.3 ± 0.5 mV per decade and a detection limit of 2×10-7. It has a fast responsetime of

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Computer-controlled ion-selective electrode switch

The construction of a microcomputer-controlled electrode switch for use in potentiometric determinations is described. This can be coupled to most of the analytical equipment usually found in laboratories, to enable a setting up of automatic systems capable of performing sequential determinations with several ion-selective electrodes. The assessment of its analytical usage and behaviour are dis...

متن کامل

Measurements with fluoride ion selective electrode

Where E0 is the standard electrode potential, R is the universal gas constant, T is the absolute temperature, z is the number of moles of electrons transferred in the cell reaction or halfreaction, F is the Faraday-constant, and cox and cred are the concentrations of the oxidized and reduced forms of the component. The potential of the hydrogen electrode is declared to be 0.000 V at all tempera...