Dynamic Performance Evaluation of Inverter Feeding a Weak Grid Considering Variable System Parameters

نویسندگان

چکیده

Interfacing a weak grid imposes challenges on distributed generators (DGs). These include transient frequency and voltage dynamics that can destabilize the system. Accordingly, this paper investigates stiffness based different scenarios of feeding DG connected to grid. Moreover, dynamic effects physical control parameters system’s stability are deeply analyzed evaluated. Specifically, complete mathematical models graphical representation carried out precisely examine impact system performance DG. Therefore, stable deployment renewable energy resources into power networks be achieved as well an efficient robust DGs ensured when grids. The obtained results show importance performed study in optimal sizing designing output filter inverter tuning dynamics. As result, proper design accurately considering all factors affect performance. also conducts detailed elaborated analyses simulations evaluate PI-controlled RC damped proposed interfacing significantly extend integration microgrids without requiring complex schemes or oversized components.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

Optimization of the Lyapunov Based Nonlinear Controller Parameters in a Single-Phase Grid-Connected Inverter

In this paper, optimization of the backstepping controller parameters in a grid-connected single-phase inverter is studied using Imperialist competitive algorithm (ICA), Genetic Algorithm (GA) and Particle swarm optimization (PSO) algorithm. The controller is developed for the system based on state-space averaged model. By selection of a suitable Lyapunov function, stability of the proposed con...

متن کامل

Performance evaluation of five level inverter for solar grid connected system

Reformations in electricity sector along with various renewable energy promotion policies has increased the importance of small grid connected photovoltaic (PV) systems utilizing single-stage single-phase inverters. To improve the performance multilevel inverter are preferred over two levels. This paper proposes a single-stage five level inverter for grid connected (PV) system. The output curre...

متن کامل

Evaluation of Reliability Parameters in Micro-grid

Evaluation of the reliability parameters in micro-grids based on renewable energy sources is one of the main problems that are investigated in this paper. Renewable energy sources such as solar and wind energy, battery as an energy storage system and fuel cell as a backup system are used to provide power to the electrical loads of the micro-grid. Loads in the micro-grid consist of interruptible...

متن کامل

Dynamic Modelling of a Compressed Air Energy Storage System in a Grid Connected Photovoltaic Plant

The use of photovoltaic (PV) cells in domestic and industrial applications has grown rapidly through the recent years. Constructing PV plants is a very smart measure to produce free electricity in large scales, especially in the countries with higher solar irradiation potential. On the other hand, compressed air energy storage (CAES) has already been proposed to be employed for energy storage a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Access

سال: 2021

ISSN: ['2169-3536']

DOI: https://doi.org/10.1109/access.2021.3111047