DYNAMIC OPTIMISATION OF DEEP-LEVEL MINE REFRIGERATION CONTROL
نویسندگان
چکیده
منابع مشابه
Optimisation of Refrigeration Compressor Controllers
Optimisation provides the means of raising or lowering the target suction pressure in a Honeywell Genus® pack controller. Suction pressure optimisation means that suction pressures are raised to the highest level allowed within defined evaporator performance limits. This provides optimum compressor energy consumption while ensuring that the refrigerated merchandise quality is maintained at the ...
متن کاملDistributed Intelligent Control For A Mine Refrigeration System - IEEE Control Systems Magazine
ne way to construct iritelligent controllers is to use an agent0 centered approach in \which the agents themselves determine the global structure of the controller and the inter-agent cooperation methods. To assess this approach, the design and testing of a distributed intelligent coritroller for a laboratory-scale mine refrigeration plant is discussed. Underlying theoretical concepts are brief...
متن کاملA Real Time Control Strategy for Optimisation of an Economised Indirect Multi-Temperature Transport Refrigeration System
This paper describes an approach for control of an economiser cycle based on the use of economiser pressure as the primary control parameter. In the study, the economiser cycle was used to optimise a multi-temperature indirect (IDX) transport refrigeration system, where hydronic secondary loops were utilised. In transport refrigeration applications, IDX systems can offer the potential to addres...
متن کاملConstrained Path Optimisation for Underground Mine Layout
The major infrastructure component required to develop an underground mine is a decline, which is a system of tunnels used for access and haulage. In this paper we study the problem of designing a decline of minimum cost where cost is a combination of development and haulage costs over the life of the mine. A key design consideration is that the decline must be navigable to trucks and mining eq...
متن کاملNumerical optimisation of a two-stage ejector refrigeration plant
Jet-refrigeration cycles seem to provide an interesting solution to the increasing interest in environment protection and the need for energy saving due to their low plant costs, reliability and possibility to use water as operating fluid. A steam/steam ejector cycle refrigerator is investigated introducing a two-stage ejector with annular primary at the second stage. The steady_state refrigera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: South African Journal of Industrial Engineering
سال: 2018
ISSN: 2224-7890
DOI: 10.7166/29-3-2060