Dynamic Lighting and Natural Ventilation in Patient Rooms at New Psychiatry Bispebjerg

نویسندگان

چکیده

Abstract This paper presents preliminary results of analyzes the indoor environmental quality (IEQ) in a full scale rotatable 1:1 mockup patient room. As initial part planning environment at new mental hospital, project seeks to uncover natural differences and limitations building, caused by geographical orientation. Examining outdoor diurnal variations their effect on environment, order create balance between one hand, daylight artificial lighting other hand demand for passive cooling, using ventilation. The analysis discuss potential health aspects fresh air proposes strategy dynamic lighting, including ventilation supplement mechanical In this article we conditions based two main parameters; 1) geographic orientation (N, S, E W) 2) season (summer winter). Based data regional conditions, way plan called Lattitude Orientation Compensated Architectural Lighting (LOCAL).

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal Comfort, Uniformity, and Ventilation Effectiveness in Patient Rooms: Performance Assessment Using Ventilation Indices

This paper describes a study of the performance of a ventilation system in a typical patient room using CFD modeling and calculations of various ventilation indices. The results show that the use of basboard heating is necessary in extreme weather conditions. In particular, good occupant conditions are virtually impossible to achieve without baseboard heating. Further, in general weather condit...

متن کامل

Study of daytime lighting at official rooms and its relation with personnel's cognitive performance, alertness, visual comfort and sleep quality.

Background and Aim: Undesirable lighting the work environment causes visual and non-visual effects in employers. The aim of this study was to compare the quantity and quality of combined and artificial lighting in daytime and its relationship with the indexes of mental performance. Methods: This study carried out at 65 rooms and on 81 employees randomly selected from different clusters. Measur...

متن کامل

Ventilation Rates and Airflow Pathways in Patient Rooms: A Case Study of Bioaerosol Containment and Removal.

Most studies on the transmission of infectious airborne disease have focused on patient room air changes per hour (ACH) and how ACH provides pathogen dilution and removal. The logical but mostly unproven premise is that greater air change rates reduce the concentration of infectious particles and thus, the probability of airborne disease transmission. Recently, a growing body of research sugges...

متن کامل

An Analysis of Natural Ventilation Function in Vakil Bazaar

Despite the similar performance of Bazaar1 in different cities of Iran, there are some the skeletal differences between markets in different climates. The Bazaar roof protects customers against natural events in any climate. The ceiling height and the sitting down of the Bazaar`s floor are determined based on the need for air circulation and movement in various climates. Hence, combination of a...

متن کامل

Dynamic Psychiatry

THE APOLOGIE AND TREATISE OF AMBROISE PARE' CONTAINING THE VOYAGES MADE INTO DIVERS PLACES, WITH MANY OF HIS WRITINGS UPON SURGERY. Geoffrey Keynes, Ed. Chicago, University of Chicago Press, 1952. xxv + 227 pp., 4 plates. $3.50. Ambroise Pare was born the son of a French barber and received no education before he entered the field of surgery other than an apprenticeship to a local barber-surgec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOP conference series

سال: 2022

ISSN: ['1757-899X', '1757-8981']

DOI: https://doi.org/10.1088/1755-1315/1099/1/012026