Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus
نویسندگان
چکیده
منابع مشابه
Dynamic contour tonometry and goldman applanation tonometry in eyes with keratoconus.
PURPOSE The dynamic contour tonometer is a nonapplanation contact tonometer designed to be largely independent of the structural properties of the cornea. Theoretically, it may measure intraocular pressure most accurately in abnormally thinner corneas. This study compares intraocular pressure measurements by dynamic contour tonometry with Goldman applanation tonometry in eyes with normal cornea...
متن کاملEvaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus
PURPOSE To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal thickness (CCT) and corneal radius of curvature (CR) on IOP measurements. METHODS Sixty-three eyes of 63 keratoconus patients were enrolled in t...
متن کاملApplanation tonometry versus dynamic contour tonometry in eyes treated with latanoprost.
PURPOSE To examine the differences between Goldmann Applanation Tonometry (GAT) and Dynamic Contour Tonometry (DCT) associated with latanoprost use. METHODS Twenty-four eyes (of 24 patients) treated with latanoprost monotherapy (latanoprost group, LG), 11 eyes (of 11 patients) not receiving prostaglandin analogs (nonlatanoprost group, NLG), and 20 eyes of 20 nonglaucomatous patients (control ...
متن کاملComparison Between Dynamic Contour Tonometry and Goldmann Applanation Tonometry
PURPOSE To compare the intraocular pressures (IOPs) measured by dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT), and to investigate the association of IOPs on eyes of varying central corneal thickness (CCT). METHODS In this prospective study, 451 eyes of 233 subjects were enrolled. IOPs were measured by GAT and DCT. CCT was measured three times and the average was cal...
متن کاملTonometry in corneal edema after cataract surgery: dynamic contour tonometry versus Goldmann applanation tonometry
INTRODUCTION Intraocular pressure (IOP) determination using dynamic contour tonometry (DCT) has been considered to be independent of central corneal thickness (CCT), while Goldmann applanation tonometry (GAT) is known to be influenced by various corneal properties. In this study, IOP was measured before and 1 day after cataract surgery using GAT and DCT to investigate the possible effects of co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinics
سال: 2006
ISSN: 1807-5932
DOI: 10.1590/s1807-59322006000600004