Dynamic column loss analysis of reinforced concrete flat slabs
نویسندگان
چکیده
منابع مشابه
Behaviour of fibre reinforced concrete slabs
This paper presents a comparison of the properties of concrete slabs when two types of fibres are added. One specimen had no fibres and acted as a control specimen. The remaining four specimens had steel and polypropylene fibres added in the volumetric ratio of 0.5% and 1.0%. The dimensions of the slab specimens were 820×820×80 mm and were supported by four rollers at their edges. A displacemen...
متن کاملNumerical Analysis of Punching Shear Failure of Reinforced Concrete Slabs
Nearly no load bearing behaviour of reinforced concrete members allows such varied interpretations and complex discussions as the shear behaviour. Especially the three-dimensional problem of the punching shear failure of reinforced concrete members is internationally discussed. Nevertheless up to now, there is no unified design approach or even an overall accepted design model. Especially for l...
متن کاملExperimental Modal Analysis of Reinforced Concrete Square Slabs
The aim of this paper is to perform experimental modal analysis (EMA) of reinforced concrete (RC) square slabs. EMA is the process of determining the modal parameters (Natural Frequencies, damping factors, modal vectors) of a structure from a set of frequency response functions FRFs (curve fitting). Although, experimental modal analysis (or modal testing) has grown steadily in popularity since ...
متن کاملFinite Element Analysis of Reinforced Concrete Column Under Lateral Load
To serve its purpose a structure must be safe against collapse and serviceable in use. Serviceability requires that deflections be adequately small to keep the cracks within tolerable limits. Although the widely followed ACI Code suggests a detailed method of deflection calculation, it often cannot exactly perceive the actual behavior of a structure. For this purpose, finite element analysis, u...
متن کاملStructural Consideration in Design of Reinforced Concrete Slabs with Openings
Over 90% of framed structures in Uganda are built from reinforced concrete. Prior to the 1990’s, most buildings had no openings in slabs, yet in city centers buildings butt against each other with widows at front and back only. This limited retail activities to front rooms of the ground floor and the buildings had to be narrow. A baseline survey of 50 shopping malls in Kampala Central Business ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2019
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2019.109453