Dynamic characteristics of a R-410A split air-conditioning system
نویسندگان
چکیده
منابع مشابه
Dynamic Characteristics of a R-410A Split Air Conditioning System
This paper presents experimental results on the shut-down and start-up characteristics of a residential split system R410A air-conditioner with a capillary tube. During shut-down, the transient characteristics are evaluated by measuring the high and low side pressures and temperatures of the system. The dynamic behavior of the system after start-up is also investigated, at the high temperature ...
متن کاملR-410A Air Conditioning System With Microchannel Condenser
This paper presents experimental results from a prototype of a microchannel heat exchanger used in a residential air-conditioning system as an air-cooled condenser. The main objectives were to analyze effects of the microchannel condenser on system performance. The commercially available system that utilizes a condenser with a round tube and plate fins was experimentally evaluated first, then t...
متن کاملPerformance Domain of Multiple-split Air Conditioning System
Multiple-split air conditioning (MSAC) system has become an attractive form of air-conditioning system for smallsized commercial and residential buildings. For a common room air conditioner, the only factor affecting the performance under a fixed outdoor and indoor condition is load rate of the indoor unit. But for the MSAC system, the indoor units will have quite different working situations u...
متن کاملA Study on a New Performance Rating Approach for a Multi-Split (VRF) Air-Conditioning System
This study starts with a survey on the end-user’s behaviour on operating a multi-split VRF air-conditioning system and progresses with reasonable assumptions and finally, mathematical models are used to generate the calculation equations. Taking a one-to-four multi-split system as an example, step by step, a new performance rating approach for a multi-split air-conditioning system is developed.
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Refrigeration
سال: 2001
ISSN: 0140-7007
DOI: 10.1016/s0140-7007(00)00088-8