A "Bioscope" system using double-sided silicon strip detectors and self-triggering read-out chips
The components and the design of a 640 by 640 channel radiation detection system based on double-sided silicon strip detectors and self-triggering read-out chips are presented. The system has been designed for applications in autoradiography and X-ray imaging in medicine, biology and other fields. Images and results from first tests of the system are shown.
متن کاملIn - Beam Test of Double - Sided Silicon Strip Detector
The response of a double-sided silicon strip detector to a 3 GeV pion beam from the Proton Synchrotron at CERN is presented. Charge matching between the pulseheights from both sides, produced by the same traversing particle, is obtained with a resolution better than 5%. The spatial resolution is measured as a function of the incident angle of the projectile, varying from 15 m at normal incidenc...
متن کاملSiliSPECT: A Double-Sided Strip Silicon Detector-Based SPECT System
This work describes preliminary test studies with a dual-headed SPECT system that utilizes a new generation of silicon double-sided strip detectors (DSSDs) (Figure 1) with a 1-mm bulk thickness and larger active area (60 × 60 mm) as compared to standard gamma-ray silicon detectors. Furthermore, major improvements in the ASIC design make this detector very suitable for low-energy imaging of smal...
متن کاملCharacterization of a double-sided silicon strip detector autoradiography system.
PURPOSE The most commonly used technology currently used for autoradiography is storage phosphor screens, which has many benefits such as a large field of view but lacks particle-counting detection of the time and energy of each detected radionuclide decay. A number of alternative designs, using either solid state or scintillator detectors, have been developed to address these issues. The aim o...
متن کاملBeam Test of the SDC Double-sided Silicon Strip Detector
A beam test was executed to evaluate the behavior of the first prototype radiation-hard double-sided silicon microstrip sensor for the SDC silicon tracking system. Pions of 4 GeV/c in a test beamline at KEK illuminated three planes of detectors. The signals were amplified, shaped, and discriminated with TEKZ bipolar analog LSI's, and the on-off levels were sampled at 10MHz clock with CMOS digit...