Double Coil-Less Fluxgate in Bridge Configuration
نویسندگان
چکیده
منابع مشابه
Micro-integrated Double Axis Planar Fluxgate
In this paper a double axis micro-integrated Fluxgate magnetic sensor is presented. The device was designed using a PCB dual axis sensor previously realized as a starting point. In the PCB version the experimental results exhibit excellent agreement with the simulations performed using a tool based on the finite element method. Using the same design approach a version of the double axis Fluxgat...
متن کاملSeparation of Signals Acquired with EMAT in Dual Coil Configuration
In this paper, the proposal of electromagnetic acoustic transducer (EMAT) in dual coil configuration with consequent application of signal de-noising algorithm is presented in detail. Dual EMAT contains two operated coils in a single housing. Both coils transmit and receive the ultrasonic signal. Based on the proposed coil configuration, two signals characterizing material structure at the same...
متن کاملResting myosin cross-bridge configuration in frog muscle thick filaments
Clear images of myosin filaments have been seen in shadowed freeze-fracture replicas of single fibers of relaxed frog semitendinosus muscles rapidly frozen using a dual propane jet freezing device. These images have been analyzed by optical diffraction and computer averaging and have been modelled to reveal details of the myosin head configuration on the right-handed, three-stranded helix of cr...
متن کاملPseudospectral double excitation configuration interaction
Recently, we have presented’ a pseudospectral formulation of the full configuration interaction (FCI) problem. The method was accurate to a mhartree after corrections, but the size of the numerical grids required made it impossible to realize any computational advantage for systems feasible with today’s hardware. In this paper, we present the first application of the pseudospectral method to tr...
متن کاملCurrent - Output Fluxgate
The current-output fluxgate may be tuned by using a serial capacitor. Such tuning increases the sensor sensitivity in the situation when the pick-up coil has a low number of turns. We achieved a signal/feedthrough ratio improvement by a factor of 5. The measured parameters fit the simplified theoretical model within 20% deviation
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Magnetics
سال: 2010
ISSN: 0018-9464
DOI: 10.1109/tmag.2009.2033339