Double-Catheter Technique for the Proper Insertion of Umbilical Venous Catheters in Newborns
نویسندگان
چکیده
منابع مشابه
Double-catheter technique for the proper insertion of umbilical venous catheters in newborns.
OBJECTIVES To document the usefulness and safety of inserting a second umbilical venous catheter in ill neonates, while a previously misplaced first catheter was still in its place. SUBJECTS AND METHODS The case series involved 25 newborn babies who were admitted to the Neonatal Intensive Care Unit, Maternity Hospital, Kuwait, over a 3-year period from 1999 to 2002. The umbilical venous cathe...
متن کاملInsertion of umbilical arterial and venous catheters.
Equipment Required Sterile prepackaged UAC and UVC sets are available in most units and contain most equipment required. This includes: dressing drapes, measuring tape, forceps, scalpel, dilator, suture scissors, three-way taps, syringes, needles. In addition, umbilical cord tape, suture material and antiseptic solution. Heparinised solution is needed for UAC flush. Full sterile scrub and gown ...
متن کاملcomplications involving central venous catheter insertion in newborns admitted to the neonatal intensive care unit (nicu)
conclusions most of the catheter-related deaths were due to severe sepsis and hemothorax, and a significant relationship was noted between infection and both the mortality rate and catheterization duration. a significant relationship was also evident between birth weight and infection rates. background developments in the use of central venous catheters have improved the treatment of critically...
متن کاملSeldinger technique as an alternative approach for percutaneous insertion of hydrophilic polyurethane central venous catheters in newborns.
The use of hydrophilic central venous catheters, percutaneously inserted by means of the Seldinger technique, was evaluated in this prospective study. Between 1988 and 1991, 138 catheters were inserted in newborns who were admitted to our neonatal intensive care unit. An adequate position of the tip, evaluated radiographically, was achieved in 130 (94.2%) of these insertions. The side effects a...
متن کاملEffects of umbilical venous catheters on arrhythmia and heart rate variability in premature newborns
Kadir Babaoğlu1, Murat Seringeç2, Gürkan Altun1, Selim Öncel3, Ayşe Engin Arısoy4 1Kocaeli University Medical Faculty, Division of Pediatric Cardiology, Kocaeli, Turkey 2Kocaeli University Medical Faculty, Department of Pediatrics, Kocaeli, Turkey 3Kocaeli University Medical Faculty, Division of Pediatric Infections, Kocaeli, Turkey 4Kocaeli University Medical Faculty, Division of Neonatology, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Principles and Practice
سال: 2005
ISSN: 1011-7571,1423-0151
DOI: 10.1159/000083919