Radiation protection at high energy electron accelerators.

An overview is presented of radiation protection at high energy electron accelerator facilities. By 'high energy' is meant the energy domain beyond a few tens of MeV, where electromagnetic showers are the determining and dominant factor for beam interactions with matter. The basic components of electron accelerators are described and their potential impact on radiation safety. The paper then co...

متن کامل

Dosimetry at high-energy accelerators

R É S U M É Les problèmes de la dosimetric dans les champs de rayonnements ionisants diffusés autour des accélérateurs de haute énergie sont présentés. Après une courte introduction sur l'historique des grandeurs physiques utilisées pour l'acquisition de l'équivalent de dose, les techniques diverses pour la dosimétrie dans des champs mixtes à haute énergie sont décrites, en commençant par des m...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

the quality control of intensity modulated radiation therapy (imrt) for oncor siemens linear accelerators using film dosimetry

introduction intensity modulated radiation therapy (imrt) has made a significant progress in radiation therapy centers in recent years. in this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. considering the complexity of this method, the quality control for imrt is a topic of interest for researchers. this article is about the various ...

متن کامل

Intraoperative radiation therapy using mobile electron linear accelerators: report of AAPM Radiation Therapy Committee Task Group No. 72.

Intraoperative radiation therapy (IORT) has been customarily performed either in a shielded operating suite located in the operating room (OR) or in a shielded treatment room located within the Department of Radiation Oncology. In both cases, this cancer treatment modality uses stationary linear accelerators. With the development of new technology, mobile linear accelerators have recently becom...

متن کامل