Dosimetric verification of IMPT using a commercial heterogeneous phantom
نویسندگان
چکیده
منابع مشابه
The use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique
Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...
متن کاملDosimetric Study of an Indigenous and Heterogeneous Pelvic Phantom for Radiotherapy Quality Assurance
Introduction: In vitro dosimetric verification prior to patient treatment plays a key role in accurate and precision radiotherapy treatment delivery. Since the human body is a heterogeneous medium, the aim of this study was to design a heterogeneous pelvic phantom for radiotherapy quality assurance. Material and Methods: A pelvic phantom was ...
متن کاملautomatic verification of authentication protocols using genetic programming
implicit and unobserved errors and vulnerabilities issues usually arise in cryptographic protocols and especially in authentication protocols. this may enable an attacker to make serious damages to the desired system, such as having the access to or changing secret documents, interfering in bank transactions, having access to users’ accounts, or may be having the control all over the syste...
15 صفحه اولEvaluation of IMRT QA Point Measurement Rocesses Using a Commercial Heterogeneous Phantom
Lung cancer is the leading cause of cancer mortality in the United States. Significant effort has been carried out in developing highly conformal dose delivery techniques using multiple coplanar beams for these patients. IMRT is being used for lung cancer treatment and has shown the potential to deliver a highly conformal dose to the target while minimizing dose to the healthy tissues and is th...
متن کاملVerification of dose calculation algorithms in a multi-layer heterogeneous phantom using films.
UNLABELLED The development of advanced radiation treatment techniques such as intensity modulated radiation therapy (IMRT) and volumetric intensity modulated arc therapy (VMAT) require more accurate dose calculation algorithms within the treatment planning systems (TPS) considering that the human body is composed of tissues of widely differing radiological properties and the characteristics of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2019
ISSN: 1526-9914
DOI: 10.1002/acm2.12535