Dosimetric study of GZP6 60 Co high dose rate brachytherapy source
نویسندگان
چکیده
منابع مشابه
Dosimetric characterizations of GZP6 60Co high dose rate brachytherapy sources: application of superimposition method
BACKGROUND Dosimetric characteristics of a high dose rate (HDR) GZP6 Co-60 brachytherapy source have been evaluated following American Association of Physicists in MedicineTask Group 43U1 (AAPM TG-43U1) recommendations for their clinical applications. MATERIALS AND METHODS MCNP-4C and MCNPX Monte Carlo codes were utilized to calculate dose rate constant, two dimensional (2D) dose distribution...
متن کاملMonte Carlo dosimetric study of the Flexisource Co-60 high dose rate source
PURPOSE Recently, a new HDR (60)Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. MATERIAL AND METHODS TWO MONTE CARLO RADIATION TRANSPORT CODES WERE USED: Penelope2008 and GEANT4. The source was centrally-position...
متن کاملA Specific Patient Quality Assurance (PSQA) procedure for a Co-60 source based High Dose Rate Brachytherapy
Introduction: In radiation therapy, accurate dose determination and precise dose delivery to the tumor are directly associated with better treatment outcomes in terms of higher tumor control and lower post radiation therapy complications. The current study aims the development and clinical application of the Patient Specific Quality Assurance (PSQA) procedures for nasopharyngea...
متن کاملTechnical note: Dosimetric study of a new Co-60 source used in brachytherapy.
The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control proce...
متن کاملDosimetric impact of source-positioning uncertainty in high-dose-rate balloon brachytherapy of breast cancer
PURPOSE To evaluate the dosimetric impact of source-positioning uncertainty in high-dose-rate (HDR) balloon brachytherapy of breast cancer. MATERIAL AND METHODS For 49 HDR balloon patients, each dwell position of catheter(s) was manually shifted distally (+) and proximally (-) with a magnitude from 1 to 4 mm. Total 392 plans were retrospectively generated and compared to corresponding clinica...