Dosimetric response of Gafchromic™ EBT‐XD film to therapeutic protons

نویسندگان

چکیده

The EBT-XD model of Gafchromic™ films has a broader optimal dynamic dose range, up to 40 Gy, compared with its predecessor models. This characteristic made suitable for high-dose applications, such as stereotactic body radiotherapy and radiosurgery, well ultra-high rate FLASH radiotherapy. purpose the current study was characterize dependence film response on linear energy transfer (LET) therapeutic protons from synchrotron. A clinical spot-scanning proton beam used LET at three dose-averaged values 1.0 keV/μm, 3.6 7.6 keV/μm. research beamline 150 Gy/s in mode 0.3 non-FLASH mode. Film data 0.9 keV/μm 9.0 were also compared. 6-MV photon reference. Both gray value method optical density (OD) calibration. Calibration results using specific OD calculation generic four-parameter NIH Rodbard function three-parameter rational fitting calibration curves. Experimental showed that is dependent, but independent rate. Goodness-of-fit analysis superior both photons. Using “specific + function” recommended.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characterization of GafChromic EBT film

The suitability of radiochromic EBT film was studied for high-precision clinical quality assurance (QA) by identifying the dose response for a wide range of irradiation parameters typically modified in highly-conformal treatment techniques. In addition, uncertainties associated with varying irradiation conditions were determined. EBT can be used for dose assessment of absorbed dose levels as we...

متن کامل

Dosimetric study of radioadaptive response of zebrafish embryos using PADC-film substrates

We found the alpha-particle priming dose which could effectively induce in vivo radioadaptive response in the embryos of the zebrafish, Danio rerio, to be 4.8e48 mGy, through the apoptotic signals scored in the embryos at 24 h post fertilization. Specially fabricated thin polyallyldiglycol carbonate (PADC) films were used as support substrates for the dechorionated embryos. During irradiation, ...

متن کامل

Laser Acceleration of Protons from Thin Film Targets

A collimated beam of fast protons, with energies as high as 10 MeV and total number of 10, confined in a cone angle of 40°±10° has been observed when a 10 TW laser with frequencies either co0 (corresponding to 1 Jim) or 2o)0 was focused to an intensity of a few times 10 W/cm on the surface of a thin film target. The protons, which originate from impurities on the front side of the target, are a...

متن کامل

Dosimetric verification of compensated beams using radiographic film

INTRODUCTION External photon beam modulation using compensators in order to achieve a desired dose distribution when brachytherapy treatment is followed by external beam radiation is a well-established technique. A compensator modulates the central part of the beam, and the dose beneath the thickest part of the compensator is delivered mostly by scattered, low energy photons. A two-dimensional ...

متن کامل

Evaluation of the therapeutic response to phototherapy at different body sites in chronic plaque-type psoriasis

Background and aim: Psoriasis is a chronic inflammatory dermatosis that affects 0.6% to 4.8% of the population. Phototherapy is commonly used in the treatment of this disease. According to the results of previous studies that showed difference in minimal erythema dose between different body sites, it seems that the responses of psoriatic lesions are also different in various body sites. O...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Precision radiation oncology

سال: 2023

ISSN: ['2398-7324']

DOI: https://doi.org/10.1002/pro6.1187