Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer

The aim of the present study was to compare radiotherapy treatment plans for gastric cancer using intensity-modulated radiotherapy (IMRT) and single/double-arc volumetric modulated arc therapy (SA/DA-VMAT) delivery techniques. A total of 29 postoperative gastric cancer patients were enrolled in this study and each patient was scheduled 5-field IMRT (5F-IMRT), 7-field IMRT (7F-IMRT), SA-VMAT and...

متن کامل

Intensity modulated radiation therapy versus volumetric intensity modulated arc therapy

The advanced developments in external beam radiation therapy (EBRT) over the past few decades have improved dose conformity to the target while minimizing dose to the surrounding organs at risk (OAR). Intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) are two commonly used EBRT techniques to treat cancer. In sliding window (SW) or dynamic IMRT, each radiati...

متن کامل

A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer

BACKGROUND To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planni...

متن کامل

A Dosimetric Comparison of Double Arc Volumetric Modulated Arc Therapy with Large Field Intensity Modulated Radiation Therapy for Head and Neck Cancer

Background: This Study Evaluate two state of Art techniques, Rapid Arc and large-field sliding window IMRT in terms of dosimetric end points and delivery time for head and neck cancer. Materials and Methods: 22 patients with head and neck cancer were selected for a planning comparative study. All patients went to CT-simulation in supine position. PTVs were delineated for two dose level of presc...

متن کامل

A Dosimetric Comparison of Intensity-Modulated Proton Therapy, Volumetric-Modulated Arc Therapy, and 4π Non-Coplanar Intensity-Modulated Radiation Therapy for a Patient with Parameningeal Rhabdomyosarcoma

Rhabdomyosarcoma (RMS) is the most common soft tissue sarcoma in children and manifests as two major histological subtypes: embryonal and alveolar. The five-year local failure rate for RMS at parameningeal sites (middle ear, mastoid region, nasal cavity, etc.) is around 17% despite multiple Intergroup Rhabdomyosarcoma Study Group (IRS) trials conducted to determine the optimal radiation treatme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Oncology Letters

سال: 2014

ISSN: 1792-1074,1792-1082

DOI: 10.3892/ol.2014.2363