Dosimetric calibration of GafChromic HD-V2, MD-V3, and EBT3 films for dose ranges up to 100 kGy

نویسندگان

چکیده

A dosimetric calibration of three types radiochromic films (GafChromicTM HD-V2, MD-V3, and EBT3) was carried out for absorbed doses (D) ranging up to 100 kGy using a 130 TBq Co60 γ-ray source. The optical densities (ODs) the irradiated were acquired with transmission-mode flatbed film scanner EPSON GT-X980. data cross-checked 20-MeV proton beam from azimuthally varying field cyclotron at Research Center Nuclear Physics in Osaka University. These experimental results not only present measurable dose ranges depending on readout wavelength, but also show consistency our hypothesis that OD response curve [log(OD)–log(D) curve] is determined by volumetric average absorption does strongly depend type radiation excitation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification

Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer configuration allows the user to eliminate side orientation dependence, which i...

متن کامل

Calibration of Gafchromic EBT3 for Dose Measurements in Low-Energy Proton Beam

The use of radiochromic film (RCF) dosimetry is widely consolidated for applications in photon, electron and proton beams. It offers several advantages, in particular, two-dimensional measurements of dose distributions with high spatial resolution, no post irradiation processing required and no daylight sensitivity. In addition, it shows small LET and energy dependence. GAFCHROMIC® EBT3 films, ...

متن کامل

Dosimetry for Small Fields in Stereotactic Radiosurgery Using Gafchromic MD-V2-55 Film, TLD-100 and Alanine Dosimeters

This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (...

متن کامل

Calibration of GafChromic EBT3 for absorbed dose measurements in 5 MeV proton beam and (60)Co γ-rays.

PURPOSE To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. ...

متن کامل

Comparing three UV wavelengths for pre‐exposing Gafchromic EBT2 and EBT3 films

Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 2021

ISSN: ['1089-7623', '1527-2400', '0034-6748']

DOI: https://doi.org/10.1063/5.0043628