Dosimetric and radiobiological comparison of CyberKnife M6TMInCise multileaf collimator over IRISTMvariable collimator in prostate stereotactic body radiation therapy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of multileaf collimator and conventional circular collimator systems in Cyberknife stereotactic radiotherapy

Multileaf collimator (MLC) technology has been newly introduced with the Cyberknife system. This study investigated the advantages of this system compared with the conventional circular collimator (CC) system. Dosimetric comparisons of MLC and CC plans were carried out. First, to investigate suitable target sizes for the MLC mode, MLC and CC plans were generated using computed tomography (CT) i...

متن کامل

Dosimetric characteristics of an electron multileaf collimator for modulated electron radiation therapy

Modulated electron radiation therapy (MERT) has been proven as an effective way to deliver conformal dose distributions to shallow tumors while sparing distal critical structures and surrounding normal tissues. It had been shown that a dedicated electron multileaf collimator (eMLC) is necessary to reach the full potential of MERT. In this study, a manually-driven eMLC for MERT was investigated....

متن کامل

Stereotactic IMRT for prostate cancer: Dosimetric impact of multileaf collimator leaf width in the treatment of prostate cancer with IMRT

The focus of this work is the dosimetric impact of multileaf collimator (MLC) leaf width on the treatment of prostate cancer with intensity-modulated radiation therapy (IMRT). Ten patients with prostate cancer were planned for IMRT delivery using two different MLC leaf widths--4mm and 10mm--representing the Radionics micro-multileaf collimator (mMLC) and Siemens MLC, respectively. Treatment pla...

متن کامل

Dosimetric performance of the new high‐definition multileaf collimator for intracranial stereotactic radiosurgery

The objective was to evaluate the performance of a high-definition multileaf collimator (MLC) of 2.5 mm leaf width (MLC2.5) and compare to standard 5 mm leaf width MLC (MLC5) for the treatment of intracranial lesions using dynamic conformal arcs (DCA) technique with a dedicated radiosurgery linear accelerator. Simulated cases of spherical targets were created to study solely the effect of targe...

متن کامل

Multileaf collimator shape matrix decomposition

An important method in cancer treatment is the use of high energetic radiation. In order to kill tumor cells the patient is exposed to radiation that is delivered by a linear accelerator whose beam head can be rotated about the treatment couch. Inevitably the healthy tissue surrounding the tumor is also exposed to some radiation. So the problem arises to arrange the treatment in a way such that...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Medical Physics

سال: 2016

ISSN: 0971-6203

DOI: 10.4103/0971-6203.181638