Dosimetric Analysis and Effect of Different Definitions of Prescription Point “A” to OAR in High Dose Rate Brachytherapy for Cervical Cancer

نویسندگان

چکیده

Purpose: Dosimetric analysis and effect of different definitions prescription point “A” to OAR in high dose rate brachytherapy for cervical cancer. Methods Materials: This retrospective comparative dosimetric study is based on the data 25 patients with histologically proven carcinoma treated HDR (high-dose-rate) brachytherapy. Patients received 21 Gy three fractions (7.0 X fractions) A (AMAN, revised Manchester definition). Further, were replanned new (AABS) as per American Brachytherapy Society/ICRU 89 which defined CT images. The compiled was then compared observed from (AMAN). Results: When AMAN normalization method used, mean bladder at 0.1cc, 1cc, 2cc 5cc obtained 1121.2±54.5, 1058.7±44.1, 875.0±38.6, 780.5±35.9, 641.2±29.5 cGy respectively. Likewise, using ICRU-89 (ABS) method, 0.1 cc, 0.2 1 2 volumes 1178±156.1,1110.0±130.8, 921.6±111.4, 826.6±101.32, 673.3±80.9 cGy, For rectum, (MAN) plans, cc,1 rectum 680±143.5, 652.53±129.8,574.25±131.1, 530±126.9, 452.5±121.2cGy, plan, 0.2cc, volume 707.5±148.1, 678.7±128.7, 596.2±135.6, 551.25±127.44 471.25±122.64 statistical difference Total Reference Air Kerma rate, V100 (cc), bladder, found significant. Conclusion: present attempts analyze differences dose, well size enclosed prescribed Isodose curve following ICRU 38 ABS-ICRU recommendations about intracavitary cervix cancer With system being more static, i.e., lesser variation geometric changes, it preferable comparison ABS system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional dosimetric considerations from different point A definitions in cervical cancer low-dose-rate brachytherapy

PURPOSE To investigate the dosimetric difference due to the different point A definitions in cervical cancer low-dose-rate (LDR) intracavitary brachytherapy. MATERIAL AND METHODS Twenty CT-based LDR brachytherapy plans of 11 cervical patients were retrospectively reviewed. Two plans with point As following the modified Manchester system which defines point A being 2 cm superior to the cervica...

متن کامل

Optimal bladder filling during high-dose-rate intracavitary brachytherapy for cervical cancer: a dosimetric study

PURPOSE The aim of this study is to compare 3D dose volume histogram (DVH) parameters of bladder and other organs at risk with different bladder filling protocol during high-dose-rate intracavitary brachytherapy (HDR-ICBT) in cervical cancer, and to find optimized bladder volume. MATERIAL AND METHODS This dosimetric study was completed with 21 patients who underwent HDR-ICBT with computed tom...

متن کامل

Uterine perforation and its dosimetric implications in cervical cancer high-dose-rate brachytherapy

PURPOSE To retrospectively assess the incidence of sub-serosal and uterine perforation of intra-uterine tandem in intracavitary high-dose-rate (HDR) brachytherapy for cervical cancer, and to evaluate its dosimetric implications on computed tomography (CT)-based treatment planning. MATERIAL AND METHODS Computed tomography images and brachytherapy plans of cervical cancer patients treated from ...

متن کامل

Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer

PURPOSE The goal is to develop a stand-alone application, which automatically and consistently computes the coordinates of the dose calculation point recommended by the American Brachytherapy Society (i.e., point A) based solely on the implanted applicator geometry for cervical cancer brachytherapy. MATERIAL AND METHODS The application calculates point A coordinates from the source dwell geom...

متن کامل

”Maximum dose” points in cervical and endometrial cancer medium dose rate brachytherapy

Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Asian Pacific journal of cancer care

سال: 2022

ISSN: ['2588-3682']

DOI: https://doi.org/10.31557/apjcc.2022.7.1.85-90